CashFlow
®
540 changegiver Pocket Guide
18
,
MEI., 1997
Address
Parameter
Range
Meaning and Actions
Notes
340
Full tube sensor errors on
tube position A, B, C
or
D
0 - 255
Range value = the sum of the codes, where:
1 / 2 / 4 / 8 = tube A / B / C / D
128 = post gate strobe error. Values are additive - for
example, a value of 6 means faults on tubes B & C.
Switch off power to the machine.Check the tops of
the tubes for coins covering the sensors. Check and
clear any jams in the acceptor.
Close the lid of the acceptor firmly, power up and
insert a coin to test the unit.
READ ONLY
341
Disabled tube at position
A, B, C
or
D
0 - 31
Range value = the sum of the codes, where:
1 / 2 / 4 / 8 = tube A / B / C / D
If necessary, use the Route Alpha 250 terminal to
enable the tube.
READ ONLY