CashFlow
®
540 changegiver Pocket Guide
,
MEI., 1997
11
Unit rejects one type of
coin or token
N.B.
With MDB applications the coin
mechanism is controlled by the
vending machine controller.
Coin or token is inhibited
Coin or token is damaged or w o r n
A tube has reached pre-set float
level, further coins are rejected
because the unit is in float mode
Check the coin/token is in the coin set, and has been enabled.
Use the Route Alpha 250 terminal to enable the coin
Discard the worn or damaged coin/token.
Press A to leave float mode and to clear any credit.
Check the tube levels, then make a vend to check that the
correct change is dispensed.
Coins are not routing
correctly
The level of coins in a tube is
covering a top-level sensor
The top-level sensor loom or the
separator loom is not connected
correctly
Wrong acceptor or separator is fitted
A tube is disabled
Check tube counts. If they are above the pre-set float levels
and automatic tube inventory is set, press Mode+A+C to
float-down the coins in the tubes.
Switch off the power, remove the cassette and release the
acceptor. Check that the top-level sensor and separator looms
are fitted correctly. Replace the acceptor and cassette. Switch
on power to the unit, insert coins and check routing.
Check that the acceptor and separator are the correct versions.
Refer to your authorised MEI distributor.
Use the Route Alpha 250 terminal to enable the tube.
Problem
Causes
Actions