Quick Start Guide
MEASURING VOLTAGE
1
3 Press either
lim
button
Lh
When connecting to a live circuit,
the voltage and frequency of
supply is automatically displayed.
TEST THE PAIR FOR ALTERNATING CURRENT AND DIRECT CURRENT VOLTAGE
..
�
l
�
For all 3 setup configurations:
V
Ac
< 10 = Proceed to the next test
V
Ac"?.
10 = Fault must be cleared
V
Dc
< 3 = Proceed to the next test
V
Dc
"?.
3 = Fault must be cleared
TIP to RING
MEASURING CONTINUITY
1
&pressDm
2
button
RING to GROUND
MEASURING INSULATION RESISTANCE
1
Test button
Lead Null
Mode
Test lock
D
i
sp
l
ay
Setup se
l
ector backl
i
ght
Results store
Ring
Tip
Primary
f
unct
i
ons
TRUE RMS
...
TIP to GROUND
click the mode
button to togggle
the continuity
buzzer ON/OFF
3 Press and hold
•jfjl
button
To lock the test, hold down either TEST button, followed
by either of the
RED
lock buttons below.
There's a S00VDC MAX Insulation Resistance Voltage Testing
as per Telecom Standards! The field pair must be OPEN at
end of loop to properly conduct an insulation resistance test.
Secondary
Test button
To store your test results:
funct
i
ons
Lead Null
1. Press lock & release
2. Using the right test/lock buttons,
scrol I unti I the test you need is
reached.
3. Press lock & release again to dis-
play the remaining options & use
the right buttons (above) to scroll
again.
4. Press lock & hold until 'Str Ok' is
displayed.