Programming Manual ETA25PS

 

 
 

 
Operation of the Programming Interface ETA25PS

 

 

 
 
 
 
 
 
 

 

 

Function 
 

Switch No. 

DIP-Switch OFF 

DIP-Switch ON 

 

Supply voltage 
 

 

5V (24V *) 

 

3.3V 

 

Sense of rotation 
 

 

CCW 

 

CW 

Operating mode 
 

 

OUT  

(measuring mode) 

 

PGO  

(programming mode) 

Programming input 
 
 

 

N  

(inactive) 

S / E  

(setting start / end 

position) 

 
Programming Procedure: 

 

A.  Before you connect the supply voltage: 

1. Configure DIP-Switch 1: Chose supply Voltage (5V (24V / 3.3V)). (*) In case that 24V supply 
voltage version was ordered it is not allowed to switch DIP switch 1 to 3.3V position.   
2. Configure DIP-Switch 2: Chose sense of rotation (rising output signal in CW or CCW direction 

 please see drawing on the right hand) 

3. DIP-Switches 3 and 4 must be set both in OFF-Position 
 
 
 
 

 

B.  Programming the start- and end position:

 

 

1. Connect power supply voltage 
2. Switch DIP-Switch 3 to ON-Position (programming mode) 
3. Put the shaft to start position and set DIP-Switch 4 for > 1s to ON and then back to OFF 
4. Put the shaft to the end position and set DIP-Switch 4 for > 1s to ON and then back to OFF 
5. Switch DIP-Switch 3 to OFF-Position (measuring mode) 

READY 
 
 

Pin-Assignment:  
Solder lugs, 5-PIN, Contact 
Spacing 2,54mm

 

 

1 = VSUP 

2 = OUT 

3 = GND 

4 = SCL 

5 = SDA 