Programming Manual ETA25PS
Operation of the Programming Interface ETA25PS
Function
Switch No.
DIP-Switch OFF
DIP-Switch ON
Supply voltage
1
5V (24V *)
3.3V
Sense of rotation
2
CCW
CW
Operating mode
3
OUT
(measuring mode)
PGO
(programming mode)
Programming input
4
N
(inactive)
S / E
(setting start / end
position)
Programming Procedure:
A. Before you connect the supply voltage:
1. Configure DIP-Switch 1: Chose supply Voltage (5V (24V / 3.3V)). (*) In case that 24V supply
voltage version was ordered it is not allowed to switch DIP switch 1 to 3.3V position.
2. Configure DIP-Switch 2: Chose sense of rotation (rising output signal in CW or CCW direction
please see drawing on the right hand)
3. DIP-Switches 3 and 4 must be set both in OFF-Position
B. Programming the start- and end position:
1. Connect power supply voltage
2. Switch DIP-Switch 3 to ON-Position (programming mode)
3. Put the shaft to start position and set DIP-Switch 4 for > 1s to ON and then back to OFF
4. Put the shaft to the end position and set DIP-Switch 4 for > 1s to ON and then back to OFF
5. Switch DIP-Switch 3 to OFF-Position (measuring mode)
READY
Pin-Assignment:
Solder lugs, 5-PIN, Contact
Spacing 2,54mm
1 = VSUP
2 = OUT
3 = GND
4 = SCL
5 = SDA