background image

 

NetFeeler 2 

CONTENTS 

1. 

Introduction

................................................................

1

 

2. 

Features

.....................................................................

2

 

3. 

Specifications

............................................................

3

 

4. 

Application

.................................................................

4

 

4.1.

 

Connect to NetAgent II ................................................. 4

 

5. 

Settings

......................................................................

5

 

5.1.

 

How to set RFID on 

NetFeeler 2

.................................. 6

 

5.2.

 

How to set Wireless Smoke/Gas sensor ...................... 8

 

5.3.

 

How to set Wireless Door / Window sensor ............... 11

 

5.4.

 

How to set wireless glass-break sensor ..................... 13

 

5.5.

 

How to set InfraRed Beam Detector........................... 15

 

5.6.

 

How to set PIR sensor................................................ 17

 

Summary of Contents for NetFeeler 2

Page 1: ...NetFeeler 2 N Ne et tF Fe ee el le er r 2 2 User Manual v10_9722...

Page 2: ......

Page 3: ...4 1 Connect to NetAgent II 4 5 Settings 5 5 1 How to set RFID on NetFeeler 2 6 5 2 How to set Wireless Smoke Gas sensor 8 5 3 How to set Wireless Door Window sensor 11 5 4 How to set wireless glass b...

Page 4: ......

Page 5: ...sor 3 Wireless Door Window sensor 4 Wireless Glass Break sensor 5 Wireless InfraRed Beam detector 6 Wireless PIR sensor When an event occurs NetFeeler 2 alarm will buzz It can also be configured to si...

Page 6: ...up to 7 individually ID d wireless Door Window sensor to detect unauthorized access q Support Wireless Smoke or Gas sensor to trigger alarm and send notification Only one ID is available per type Mor...

Page 7: ...elative Humidity non condensing Accuracy 3 0 Relative Humidity Response Time 10 Sec Temperature Range 40 to 75 40 to 75 Temperature Specification Detection Range 40 to 70 Accuracy 3 Response Time 10 S...

Page 8: ...NetFeeler 2 4 4 Application 4 1 Connect to NetAgent II n Monitor environment data via a standard web browser o Send Email when an event occurs p Powered either directly from NetAgent II Fig 1 Conect t...

Page 9: ...ription Red LED Power Yellow LED Alarm Indicator Reset button To turn off alarm Power supply from NetAgent II RS232 port To connect to NetAgent II 3 port models RFID Switch Used for pairing NetFeeler...

Page 10: ...ler 2 6 5 1 How to set RFID on NetFeeler 2 n Set RFID switch 1 and 2 on o Set RFID switch 3 to 8 off Once set the combinations will be used to pair other wireless device to NetFeeler 2 Fig 2 NetFeeler...

Page 11: ...tings Only the binary reference for smoke and gas sensors are fixed The binary reference from 1 to 7 are interchangeable Where 1 or short pins H and N 0 or short pins L and N Default Sensor Type Binar...

Page 12: ...ontinuous buzz when is detected Gas sensor can detect presence of coal gas natural gas and liquefied petroleum gas When a leakage is detected the gas sensor will buzz An external 9 12V power input is...

Page 13: ...nsor with NetFeeler 2 Set these DIP as follows n DIP A0 to A1 set to on Connect pins from row H with middle pin using a jumper see illustration below o DIP A2 to A7 set to off Connect pins from row L...

Page 14: ...er 2 10 3 The second set of DIP switch show 4 sets of pins This set allow NetFeeler 2 to identify the type of sensor Sensor Type DIP settings Gas 0010 Smoke 1010 Fig 4 Wireless Smoke Gas Sensor defaul...

Page 15: ...window When there is an intrusion the sensor will signal NetFeeler 2 to sound an alarm To setup 1 Open the Door Window sensor casing use a flat head screwdriver and pry it open from the bottom Inside...

Page 16: ...IP A2 to A7 set to off Connect pins from row L and row N using a jumper Fig 5 Wireless Door Window sensor DIP Switch Sensor Type DIP settings Door Window 1011 Fig 6 Wireless Door Window sensor D0 to D...

Page 17: ...against unauthorized access by breaking glass window door Install the sensor on the wall or ceiling next to the glass window door If the glass is broken NetFeeler 2 will sound an alarm Note An externa...

Page 18: ...r the smaller DIP switch PCB as shown in Fig 7 3 Set DIPs A0 to A7 the same as the wireless smoke gas sensor in section 5 2 above Fig 7 Wireless glass sensor DIP switch Sensor Type DIP settings Glass...

Page 19: ...Beam is interrupted the detector will sound an alarm and send a signal to NetFeeler 2 Note An external 9 12V power input is required To setup 1 Hold both caps black on the InfraRed Beam detector and p...

Page 20: ...Settings NetFeeler 2 16 Fig 9 InfraRed Beam detector DIP Switch Sensor Type DIP settings InfraRed Beam detector 0011 Fig 10 InfraRed Beam detector default Code Right DIP Switch...

Page 21: ...ered by sudden changes in temperature over the detection range PIR sensor is normally installed in important rooms on walls ceiling or passageway PIR will be triggered when there is an unauthorized ac...

Page 22: ...et the first 8 DIP switches from LEFT to RIGHT the same as in Section 5 2 3 Set the next for DIPs 13 to 10 from RIGHT to LEFT Fig 11 PIR DIP switch Sensor Type DIP settings PIR 1001 Fig 12 PIR code fr...

Reviews: