background image

 

Hyperion 971IPS

Long-Range DC Bar

 

Operating Manual

Hyperion 960IPS

Mid-Range DC Bar

v1.02

Summary of Contents for Hyperion 960IPS

Page 1: ...Hyperion 971IPS Long Range DC Bar Operating Manual Hyperion 960IPS Mid Range DC Bar v1 02...

Page 2: ......

Page 3: ...visit www meech com Meech Static Eliminators Ltd 01 07 2020 Contents Introduction 3 Unpacking and Inspection 4 Contents 4 Options 4 Features and Benefits of Hyperion 960IPS 5 Installation 8 Operation...

Page 4: ......

Page 5: ...ional status of the bar and advises when the bar requires cleaning Demanding installations can take advantage of the adjustable output of the 960 IPS Using the optional Hyperion BarMaster remote progr...

Page 6: ...age If damage is evident do not destroy the carton or packing material and immediately notify the carrier of a possible damage claim Shipping claims must be made by the consignee to the delivering car...

Page 7: ...hockless Emitters The Titanium emitter pins on the 960IPS are resistively coupled to the high voltage supply This avoids sparking and operator shocks Sealed Construction IP66 construction allows the b...

Page 8: ...her the ionising equipment needs routine maintenance or whether there is a more serious system failure The flexible configuration of the alarm system allows the alarm lines to be interfaced with PLC s...

Page 9: ...bar features a divider to increase the surface tracking distance between the two rows of high voltage pins It is important to clean this area during cleaning operations T Slot The bar is mounted using...

Page 10: ...d 600mm from the target surface The bar should be mounted securely using all the M4 T bolts provided with the bar Correct positioning of the bar is vital for effective static control There must be no...

Page 11: ...rt range over a web or sheet the bars must be positioned away from surfaces and rollers as shown in the following diagrams Your Meech distributor will be able to assist with questions regarding positi...

Page 12: ...hree wire IEC C5 cable The ground connection must be correctly connected at the mains connection The 960IPS should also be grounded by it s grounding post to provide additional safety Connection using...

Page 13: ...0V 24V Connection using Meech 24V DC power supply Meech 24V DC supplies are grounded internally It is important that the mains connection offers a ground connection Two pin outlets without a ground co...

Page 14: ...C input The output impedance of the signal is 10k The output can also be configured to power an external relay to provide volt free contacts for other monitoring systems Using a BarMaster remote progr...

Page 15: ...is is given by the configuration of the Alarm True setting using the BarMaster Alarm True hi This means the logic on both the alarm pins is active high Alarm True lo This means the logic on both the a...

Page 16: ...24VDC on the alarm pin This configuration is the same for both alarm pins pin 2 and pin 4 Simplified Diagram of NPN output Logic Table Alarm True Hi Start State Solid Green Flashing Red Solid Red Whi...

Page 17: ...d pin 4 Simplified Diagram of NPN output Logic Table Alarm True Hi Start State Solid Green Flashing Red Solid Red White Hi Lo Hi Hi Black Hi Lo Lo Hi Alarm True Lo Start State Solid Green Flashing Red...

Page 18: ...of NPN output Logic Table Alarm True Hi Start State Solid Green Flashing Red Solid Red White Hi Lo Hi Hi Black Hi Lo Lo Hi Alarm True Lo Start State Solid Green Flashing Red Solid Red White Hi Hi Lo...

Page 19: ...should be set depends on the ionising product and the distance to the target object Maintenance Ionising bars become contaminated with usage Dirt build up on the body of the ioniser and particularly o...

Page 20: ...t Finding To reduce the time it takes to resolve a problem with a Hyperion product the following process must be completed before requesting assistance from Meech The information below shows what is r...

Page 21: ...on c Frequency d Balance e Output voltage f Alarm g Ion Level h Reset Ion Ref i Alarm True Hi or Lo j Output drive 3 Status of the LED i e solid green flashing red solid red flashing green 4 Please pr...

Page 22: ...oltage to 7500V and ensure the ion level reads 99 and the LED is green a If Ion level is 0 bar is faulty b If 10 59 with a 60 alarm setting return to the clean bar section If after cleaning a 80 99 Io...

Page 23: ...reen LED Meaning BarMaster remote programmer is connected Action After programming reconnect directly to the power supply to resume normal operation Flashing Red LED Likely cause Contamination causing...

Page 24: ...e bar directly to Meech Static Eliminators Ltd or your local Meech Distributor All products returned to the factory MUST be accompanied by a return authorisation number and must be shipped prepaid For...

Page 25: ...Voltage Wiring 24V DC Supply Suits installation on modern machinery Integrated Power Supply Removes the need for high voltage wiring Construction FR ABS Mounting T Slot with M4 x 20 studs Emitters Sh...

Page 26: ...length 45 0 30 0 LED Indicator Earth Connection Murr Power Connection 3 0 05 08 2019 25 0 100 0 STANDARD LENGTHS TOTAL LENGTH NOMINAL ACTIVE LENGTH RESISTORS NO MOUNTING STUDS 400 400 8 2 500 500 10 2...

Page 27: ...claration of Conformity Equipment Model 960IPS Ionising bar Applicable Harmonised standards EMCD EN 61000 6 4 2007 A1 2011 EN61000 6 2 2005 EC Council Directives Electromagnetic Compatibility Directiv...

Page 28: ...0 1 800 232 4210 Fax 1 330 564 2005 email info meech com Meech Shavotech 29 2 Kharadi Off Pune Nagar Road On Old Kharadi Mundhwa Road Pune 411014 Maharashtra India Tel 91 0 703 093 8211 91 0 741 000 4...