background image

 

PRO

 

AS1

 

PRO

 

AS2

Summary of Contents for PRO AS1

Page 1: ...PRO AS1 PRO AS2...

Page 2: ...lation and placement of unit 4 OPERATION To turn the unit on 4 To select various modes 4 To turn the unit off 5 iKLINN FUNCTION To select duration of iKlinn function 5 MAINTENANCE AND SERVICING Regula...

Page 3: ...entilation holes 5 Do not press the on off button or remove the unit when your hands are wet 6 Switch off the unit before cleaning the unit 7 Do not modify disassemble or repair the unit by yourself 8...

Page 4: ...sed to condensation due to rapid and drastic temperature fluctuations The unit should only be used in temperatures between 5 35 C 6 Avoid locations where the unit is exposed to water droplet basin are...

Page 5: ...3 DEVICE IDENTIFICATION PRO AS1 AS2 1 2 3 4 PRO AS1 AS2 unit Cerafusion Cartridge Mounting bracket Connector Cartridge cover On Off switch Control panel Ventilation holes 1 2 3 4 5 6 7 8 5 6 8 7...

Page 6: ...on GETTING STARTED OPERATION Control button LED lights Infrared TO TURN THE UNIT ON 1 Once the unit is fitted into an existing electric socket it is automatically connected to the power Press to turn...

Page 7: ...e iKlinn function is specially designed to initiate instant cleaning as required To activate iKlinn press the Control button for five 5 seconds Once activated the LED lights will start blinking Select...

Page 8: ...NCE SERVICING Minimal maintenance is required for the CerafusionTM cartridge It is recommended to clean the cartridge periodically by using the nail provided or equivalent to clean the edges of the me...

Page 9: ...it serviced 3 There is no hissing sound after I changed the cartridge First switch off the unit and take out the cartridge Then check if the cartridge is broken Brush off any dust or grease on the sur...

Page 10: ...tion to be performed ONLY by a Certified Electrician 1 Remove cartridge cover 2 Insert the cartridge into the opening ensuring that the white and metalic surface is facing the ventilation holes Wall s...

Page 11: ...lock as shown after Step 3 PRO AS1 PRO AS2 DESCRIPTION PRO AS1 1 Push the plastic cover securely into place PRO AS2 1 Insert the stainless steel cover and fasten screw into place Cartridge lock OPTION...

Page 12: ...10 PRO AS1 PRO AS2 DESCRIPTION 1 To secure the unit to the wall mounting insert the screws provided and fasten 1 Attach PRO AS1 AS2 to the mounted bracket Bracket Bracket STEP 4 STEP 5...

Page 13: ...t2 28m2 1 100 gram 1 year limited Remote control PRO AS1 Casing Interchangeable Cartridge Cartridge Option Installation Input Voltage Output Current max Power Consumption Functions Dimensions Operatin...