Media5 Mediatrix G7 Series Manual Download Page 7

1.  

2.  
3.  

4.  
5.  
6.  

7.  
8.  
9.  

10.  

11.  

1.  

a.  

b.  

c.  

2.  
3.  
4.  

Result
The Power LED on the unit will be flashing when the unit performs a DHCP server query. It will become solid once it successfully gets an IP address from 
the DHCP server. At this point, you can now use the DHCP IP address to access your unit's management interface.

Top

Connecting the Mediatrix Unit Using a Static IP Address

Before you begin

Your network interface must be set with an IP address in the 192.168.0.0/24 subnet (e.g. 192.168.0.11).
You must use an IPv4 Network.
Make sure that your network connection is working.

Steps

Make sure an adequate earth ground connection has been made between the grounding screw on the back of the Mediatrix unit and an 
appropriate grounding point in your site.
Warning: Adequate earth grounding connection of the Mediatrix unit is mandatory to avoid any damage or injuries.
Wear an ESD wrist strap, ensuring it makes good contact with your bare skin.
Attach the ESD wrist strap end to an earth ground (grounding screw on the back on the Mediatrix unit or unpainted bare metal spot of a grounded 
equipment rack).
Make sure the unit's power switch is OFF.
Make sure the circuit breakers of power sources used to power the Mediatrix unit are OFF.
Make sure the provided AC Power Cord is connected into the POWER connector located on the back of the Mediatrix unit and in an appropriate 
AC electrical outlet.
Connect a 10/100/1000 BaseT Ethernet RJ-45 cable into the 

 Ethernet connector of the Mediatrix unit.

ETH5

Connect the other end of the cable into your PC.
Validate the installation.
Turn ON the power sources that are used to power the Mediatrix unit at the circuit breaker.
Note: When the unit is brought from a cold to a warm environment, condensation, that might be harmful to the unit, may occur. If this is the case, 
wait one hour before connecting the power cord.
Turn On the power switch of the Mediatrix.

Result
You can now use the 192.168.0.10 IP address to access your unit's management interface.

Top

Verifying the Installation

Steps

Contact the Mediatrix unit via the Web Browser, or go to step 2

In your Web browser, enter the IP address used by your Mediatrix unit to communicate with the Web interface.

If your computer is connected to the Ethernet port, commonly used to be connected to the Local Area Network (LAN), i.e. ETH2 
on most devices, use the 192.168.0.10 IP address
If your Mediatrix unit is configured to use a DHCP server with IPv4, use the provided DHCP server IP address.

Enter 

 as your username and leave the password field empty.

public

Note: The 

 username account has administrator rights.

public

Note: You can also use 

 as a username and 

 as password.

admin

administrator

Click 

.

Login

Contact the Mediatrix unit with an SNMP browser, or
Contact the Mediatrix unit via the CLI, or
Ping the Mediatrix unit.

Top

Cables

Gigabit Ethernet Connection (RJ-45)

Caution: Always use standard telecommunication cables with a minimum of 26 AWG wire gauge.

Gigabit Ethernet requires all four pairs to be present.
Category 5 cables can be used for 10/100 Base T-Connections.
Category 5e or 6 cables are recommended for Gigabyte Ethernet.
It is possible to use either a crossover or a straight Ethernet cable as the Mediatrix units perform automatic MDI/ MDIX detection, meaning that 
they adapt to the type of cables connected to them. The Auto MDI/ MDIX feature only works when the unit are configured in auto detect mode, 
which is the default mode.

Summary of Contents for Mediatrix G7 Series

Page 1: ...cue Interface Factory Reset Performing a Factory Reset Standards Compliance and Disclaimers Supported Standards Federal Communications Commission FCC Disclaimer Innovation Science and Economic Development Canada ISED Disclaimer CE Marking RoHS China Other Disclaimers FXO Card Standards of Compliane and Disclaimers FXO Card Supported Standards FXO Card Federal Communications Commission FCC Disclaim...

Page 2: ...aution The RJ 11 cable should comply with UL 1863 and CSA C22 2 No 233 standards Top General Safety Practices Warning Do not use this product near water for example near a bath tub wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool Warning Do not expose the unit to rain or moisture to avoid any shock hazard Warning Do not use the telephone to report a gas leak in the v...

Page 3: ...must be followed Install the Mediatrix unit on a standard 48 26 cm 19 in equipment rack on a flat surface desk table etc Install the Mediatrix unit in a well ventilated location where it will not be exposed to high temperatures or humidity Storage temperature 20ºC to 70ºC Operating temperature 0ºC to 40ºC Caution If the unit is installed in a closed environment or on a multi unit rack the ambient ...

Page 4: ...ergent wring well and then wipe off Use a dry cloth to dry the surface Top Mounting Tools and Equipment Tools Screwdriver as required for attaching brackets to rack ESD wrist strap Earth ground cable Warning The earth ground cable should be the same size 18 AWG minimum as the earth cable of the provided power cord Otherwise make sure the earth ground cable meets the standards and requirements of y...

Page 5: ...default used for uplink WAN connection 14 ETH2 ETH3 ETH4 ETH5 10 100 1000 BaseT Ethernet RJ 45 connector for access to a LAN WAN or computer These ports are used by default for LAN connections 11 FXS card with 4 FXS ports RJ 11 connector for phone fax PBX FXS connection 12 FXO card with 4 FXO ports RJ 11 connector for PSTN PBX FXS connection 13 BRI card with 4 BRI ports Up to four RJ 48C connector...

Page 6: ...trap ensuring it makes good contact with your bare skin Attach the ESD wrist strap end to an earth ground grounding screw on the back on the Mediatrix unit or unpainted bare metal spot of a grounded equipment rack Make sure the unit s power switch is OFF Make sure the circuit breakers of AC power sources used to power the Mediatrix unit are OFF Make sure the provided AC power cord is connected int...

Page 7: ...power the Mediatrix unit at the circuit breaker Note When the unit is brought from a cold to a warm environment condensation that might be harmful to the unit may occur If this is the case wait one hour before connecting the power cord Turn On the power switch of the Mediatrix Result You can now use the 192 168 0 10 IP address to access your unit s management interface Top Verifying the Installati...

Page 8: ...ote The Mediatrix unit PRI ports can be used as a T reference point but not as U reference points 2 wire Never connect a U PSTN line or a U TE into the Mediatrix unit PRI ports Pin NT Mode TE Mode 1 Transmit 2 Receive 2 2 Transmit 1 Receive 1 3 Not connected Not connected 4 Receive 2 Transmit 2 5 Receive 1 Transmit 1 6 Not connected Not connected 7 Not connected Not connected 8 Not connected Not c...

Page 9: ...s wired so that pins 3 and 4 are connected to the Ring and Tip which meets the EIA TIA IS 968 and CS 03 Issue 8 Part III requirements Pin Function 1 Not used 2 Not used 3 Ring 4 Tip 5 Not used 6 Not used Top Troubleshooting Locating the Product Serial Number Before you begin Warning Make sure your unit is powered off Steps Flip the unit The serial number is located underneath the unit Caution Use ...

Page 10: ...Cancel an action that was started Revert to known factory settings if the Mediatrix unit refuses to work properly for any reason or the connection to the network is lost Reconfigure a unit The button will generate different actions depending on the amount of time the button is held Reset Default IMPORTANT It is the LED pattern that will indicate the action that is being applied to the unit The act...

Page 11: ...ctory rights ServicesAaaType table Each service will be configured to use Local authentication and no accounting mechanism CLI EnableTelnet Disable TelnetPort 23 EnableSsh Enable SshPort 22 InactivityTimeOut 15 HOC ManagementInterface Rescue SNMP Port 161 EnableSnmpV1 Enable EnableSnmpV2 Enable EnableSnmpV3 Enable Web ServerPort 80 SecureServerPort 443 Top Performing a Partial Reset Before you beg...

Page 12: ...is useful if you accidentally pushed the button and do not need any action to be applied Release the paper clip Result All configuration parameters are reset to their default value The unit can then be contacted via its WAN interface DHCP provided IP address ETH1 or WAN on the 4102S or via its LAN interface default IP address 192 168 0 10 ETH2 or LAN on the 4102S Top Standards Compliance and Discl...

Page 13: ...m FCC Compliance Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Top Innovation Science and Economic Development Canada ISED Disclaimer This Class B digital apparatus comp...

Page 14: ...s harm to the telephone network the Telephone Company may discontinue your service temporarily If possible they will notify you in advance but if advance notice is not practical you will be notified as soon as possible You will be informed of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect th...

Page 15: ...unity to maintain uninterrupted telephone service If you experience trouble with this telephone equipment please contact Media5 for information on how to obtain service or repairs The telephone company may ask that you disconnect this equipment from the network until the problem has been corrected or until you are sure that the equipment is not malfunctioning This equipment may not be used on coin...

Page 16: ... 23 users 231 230 users 232 2300 users I I I Profiles Software options MX0 Mediatrix default MX1 SW option group 1 GV0 SW option group 2 EN0 SW option group 3 MT0 SW option group 4 J SLA Support options 0 No SLA included in SKU must be separate line on PO 1 1 year SLA support HW warranty 5 5 year HW warranty K K SW license Software options 0 0 no licence 0 1 Survivability field H H H indicates the...

Page 17: ...nfiguration of a specific technical action such as performing a firmware upgrade Hardware installation guide They provide the detailed procedure on how to safely and adequately install the unit It provides information on card installation cable connections and how to access for the first time the Management interface User guide The user guide explains how to customise to your needs the configurati...

Reviews: