![Mect MPNE1001 Series User Manual Download Page 33](http://html1.mh-extra.com/html/mect/mpne1001-series/mpne1001-series_user-manual_1759153033.webp)
Inputs/outputs modules: MPNE
Mect Srl
32
ME7087_13 04/21
22
MPNE_PWM_OUT24_
OUT23_DC
UINT
0
114
[RW]
Duty Cycle for configured channels
such as PWM
Bit 0..7 –HEX Duty Cycle – output 23
Bit 8..15–HEX Duty Cycle – output 24
MPNE_ShuntExp1
UINT
0
115
[RO]
Value in A x100. Current measured in
module 06 slot 1
MPNE_ExpDigitalOut
Config25_32
UINT
0
116
[RW]
Configuring digital outputs module 06
(two bits per channel)
00: Standard output (default)
01: monostable
10: PWM with duty cycle at 50% (only
for outputs 30, 31 and 32)
11: PWM with duty cycle from 0% to
100% (only for outputs 30, 31 and 32)
MPNE_ExpPulseWidth2
_ms
UINT
0
117
[RW]
Pulse duration (ms) for outputs
configured as monostable
MPNE_Frequency_PWM2
UINT
0
118
[RW]
PWM output rate for channels defined
as PWM
MPNE_PWM_OUT30_
OUT29_DC
UINT
0
119
[RW]
Duty Cycle for configured channels
such as PWM
Bit 0..7 not used
Bit 8..15 –HEX Duty Cycle – output
30
MPNE_PWM_OUT32_
OUT31_DC
UINT
0
120
[RW]
Duty Cycle for configured channels
such as PWM
Bit 0..7 –HEX Duty Cycle – output 31
Bit 8..15–HEX Duty Cycle – output 32
MPNE_ShuntExp2
UINT
0
121
[RO]
Value in A x100. Current measured in
module 06 slot 2