1.  SPECIFICATIONS

1.1 General Specification

Display

n

3¾ digit liquid crystal display (LCD) with a
maximum reading of 3999.

Polarity

n

Automatic, positive implied, negative polarity
indication.

Overrange

n

(OL) or  (-OL)  is displayed.

Zero

n

Automatic.

Low battery

n

“        ” is displayed when the battery

indication

voltage drops below the operating level.

Measurement

n

3 times per second, nominal.

rate

Operating

n

0°C to 50°C at < 70% relative humidity.

Environment

Storage

n

-20°C to 60°C, 0 to 80% R.H. with battery

Temperature

removed from meter.

Power

n

Two  1.5V  ‘AAA’  Size Battery

Battery life

n

200 hours typical

Dimensions

n

247mm (H) X 76mm (W) X 39mm (D)

Weight

n

465 grams approx.

Accessories

n

One  pair of test leads, instruction manual,
1.5V batterys (installed), Carring Case,

Maximum Jaw

n

Can measure round cables upto 43mm

Opening

dia & Flats (Bus Bar) 65mm x 16mm

DC VOLTAGE (Auto Ranging)

Ranges

: 4V, 40V, 400V, 1000V

Accuracy

: ± (0.5% rdg + 4 dgt) on 4V

± (0.7% rdg + 4 dgt) on 40V & 400V
± (1% of rdg + 4 dgt) on 1000V

Resolution

: 1mV to 1V

Input Impedance

: 10M

V

 on all ranges except,

11M

V

 on 4V

Overload Protection : 1200V DC/800V AC

AC VOLTAGE (Auto Ranging) 40-500Hz

Range

: 4V, 40V, 400V, 750V

Accuracy

: ± (1.0% rdg + 8 dgt) on all ranges except,

± (1.5% rdg + 8 dgt) on 750V

Resolution

: 1mV to 1V

Input Impedance

: 10M

V

 on all ranges except, 11M

V

 on 4V

Overload Protection : 1200V DC/800V AC

RESISTANCE (Auto Ranging)

Range

: 400

V

, 4K

V

, 40K

V

, 400K

V

, 4M

V

, 40M

V

Accuracy

: ± (0.7% rdg + 4 dgt) on all ranges except

± (1.2% of rdg + 4 dgt) on 4M

V

± (2.5% of rdg + 4 dgt) on 40M

V

1.2 Electrical Specification
Accuracies are ± (% r number of digits) at 27 ± 5°C and
humidity of less than 75% RH.
AC CURRENT (50-60Hz)

Range

Accuracy

Overload Protection

40A

±(3% + 4dgt)

1000A AC Max.

400A / 1000A

±(2% + 4dgt)

for 1 minute

Resolution

: 0.1

V

 to 0.01M

V

Test Current

: 0.7mA on 400

V

, 0.1mA on 4K

V

,

30µA on 40K

V

, 4µA on 400K

V

Overload Protection : 500V DC/AC

Continuity Check

Threshold Level

: 40

V

 Approx.

Response Time

: 1m Sec. Approx.

Open Circuit Voltage

: 0.4V Approx.

Indication

: ‘   ’ is displayed on LCD and buzzer sounds

at continuity.

Overload Protection

: 500V DC / AC

Diode Test

Measurement Current   : 1.0 ± 0.6 mA Approx.

Open Circuit Voltage     : 0.4V Approx.

Overload Protection

: 500V DC / AC

Frequency (Auto Ranging)

Range

: 10.00Hz, 50.00Hz, 500.0Hz, 5.000kHz,

50.00kHz, 500.0kHz

Accuracy

: ± (0.5% rdg + 2 dgt)

Sensitivity

: 3V

Overvoltage Protection : 200V DC or AC peak

% Duty Cycle (Auto Ranging)

Range

: 1% to 90%

Accuracy

: ± (0.5% rdg + 5 dgt)

Resolution

: 0.1%

Overvoltage Protection : 200V DC or AC peak

Capacitance (Auto Ranging)

Range

: 40nf, 400nf, 4

m

f, 40

m

f, 100

m

f

Accuracy

: ± (5% rdg + 10 dgt)

Resolution

: 0.01nf to 0.1

m

f

Reviews: