Instruction Manual 

Battery Chargers 
 
        NOVA-1000F Series: 
 
 

 
 

Safety Rules and General Warnings 

 

 

Persons, who are not able to use the charger in a safe way, because of their physical, sensory or mental incompetence, or because of their 
lack of experience, should not use without the control or instruction from a skilled or qualified person. 

 

The charger runs with 100-240 Volts alternating current, which is not suitable for children – Danger of Life. And beware of risk of electric shock 
at all times.   

 

Ensure sufficient air ventilation; do not cover the vent outlet while charging in progress.     

 

Avoid flammable gases, solvents or vapours all the time. Prevent open flame or sparks while charging in progress. Explosion RISK! 

 

The charger is exclusively designed for charging rechargeable batteries and must not be used for other purposes. Corresponding model should 
be selected for particular lithium-based or lead-based batteries. 

 

You should take into consideration of the charging instructions issued by the battery manufacturer before charging. Check also if the charge 
profile fits your battery and application.   

 

DO NOT OPEN or DISMANTLE the charger. Repair work must only be processed by authorized technical staff. 

 

If the mains connection of the charger is damaged, it must be replaced with an original wire which is available at MEC or authorized dealers. 

 

NEVER place the charger on top of the battery while charging in progress. 

 

The charger should be protected against direct solar radiation or temperatures over 40°C. 

 

In case of obvious damage or malfunctioning, disconnect the charger from the mains supply and protect against unintended reconnection. 

 

The DC cable must not be cut, shortened or extended under any circumstances.   

 

Keep the charger in dry room (rel. humidity <80%). Clean with dry cloth only. Avoid fluid of any kind to get into the charger. 

 

Special Features 

 

 

IP20 Load-dependent fan cooling; spray-painted metal housing 

 

Microprocessor-based 4-Step charging technology with soft start and automatic re-start of the charge cycle 

 

Battery 

"

wake-up

"

 function by sending out programmed 

"

wake-up

pulses 

 

Optimal and gentle charging for the greatest possiblity of charge cycles guaranteed with high frequent combinatorial circuit technology 

 

5 Selectable battery types (GEL, AGM, WET, Calcium, +PS-Mode) and built-in battery temperature sensor for models targeting lead-based 
batteries 

 

LED indicators showing corresponding charge status and errors 

 

Protection against short circuit, reverse polarity, over temperature or overload 

 

Product Configuration

 

 
Models Targeting Lithium-based Batteries 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. 

IR-Interface LEDs 

2. 

Red Mains LED 

3. 

Yellow Charge LED 

4. 

Green Full LED 

5. 

Red Error LED 

6. 

Cooling Fan 

IP20 Load-dependent fan-cooled. With one (1) or multiple,                                                                                                                   
selectable charge profiles, customized parameters.                                                                                                                                                                   
CAN-bus / Ignition-Lock (optional). 

Reviews: