ATLAS-300 Series:

Safety Rules and General Warnings

Persons, who are not able to use the charger in a safe way, because of their physical, sensory or mental incompetence, or because of their
lack of experience, should not use without the control or instruction from a skilled or qualified person.

The charger runs with 100-240 Volts alternating current, which is not suitable for children – Danger of Life. And beware of risk of electric shock
at all times.

Avoid flammable gases, solvents or vapours all the time. Prevent open flame or sparks while charging in progress. Explosion RISK!

Ensure sufficient air ventilation and prevent open flame or sparks while charging in progress.

The charger is exclusively designed for charging rechargeable batteries and must not be used for other purposes. Corresponding model should
be selected for particular lithium-based or lead-based batteries.

You should take into consideration of the charging instructions issued by the battery manufacturer before charging. Check also if the charge
profile fits your battery and application.

DO NOT OPEN or DISMANTLE the charger. Repair work must only be processed by authorized technical staff.

If the mains connection of the charger is damaged, it must be replaced with an original wire which is available at MEC or authorized dealers.

NEVER place the charger on top of the battery while charging in progress.

The charger should be protected against direct solar radiation or temperatures over 40°C.

In case of obvious damage or malfunctioning, disconnect the charger from the mains supply and protect against unintended reconnection.

The DC cable must not be cut, shortened or extended under any circumstances.

Special Features

IP65 Passive cooling; extruded aluminium-alloy housing

Microprocessor-based 4-Step charging technology with soft start and automatic re-start of the charge cycle

5 Selectable battery types (GEL, AGM, WET, Calcium, +PS-Mode) and built-in battery temperature sensor for models targeting lead-based
batteries

LED indicators showing corresponding charge status and errors

Protection against short circuit, reverse polarity, over temperature or overload

Battery recovery function for attempting to revive a deeply discharged or

"

dead

"

battery with recurring series of voltage/current pulses

Product Configuration

Models Targeting Lithium-based Batteries

1.

Protective Vent

2.

AC Cable

3.

DC Cable

4.

IR-Interface LEDs

5.

Green Mains LED

6.

Yellow Charge LED

7.

Green Full LED

8.

Red Error LED

IP65 water resistant, microprocessor-based. With one (1) or or
multiple, selectable charge profiles, customized parameters.
CAN-bus / Ignition-Lock (optional).