Page 17
1330SE - Servce & Parts Manual
November 2021
Secton 10 - Mantenance
Frequent Inspection Checklist
THIS CHECKLIST MUST BE USED AT 3-MONTH INTERVALS OR EVERY
150 HOURS OF MACHINE USE, WHICHEVER OCCURS FIRST. FAILURE
TO DO SO COULD RESULT IN DEATH OR SERIOUS INJURY.
Frequent Maintenance Inspections should be conducted by qualified service technicians only.
Photocopy the Frequent Inspection Checklist page from the Operator’s Manual to keep record of
this inspection. Keep inspections records up to date. Record and report all discrepancies to your
supervisor.
Perform all checks listed on Pre-Start Inspection, then proceed with the following checks.
Hydraulic Fluid
Inspect the condition of hydraulic fluid in the reservoir.
Oil should be a clear and amber in color.
Batteries
Proper battery condition is essential to good machine performance and operational safety. Improper
or damaged cables and connections can result in component damage and hazardous conditions.
ELECTROCUTION / BURN HAZARD. CONTACT WITH ELECTRICALLY
CHARGED CIRCUITS COULD RESULT IN DEATH OR SERIOUS INJURY.
REMOVE ALL RINGS, WATCHES AND OTHER JEWELRY.
BODILY INJURY HAZARD. BATTERIES CONTAIN ACID. AVOID SPILLING
OR CONTACTING BATTERY ACID. NEUTRALIZE BATTERY ACID SPILLS
WITH BAKING SODA AND WATER.
Put on protective clothing and eye wear.
Slide out the component tray from the chassis.
Be sure that the battery cable connections are free of corrosion.
Note: Adding terminal protectors and a corrosion preventative sealant will help eliminate
corrosion on the battery terminals and cables.
Be sure that the battery retainers and cable connections are tight.
Fully charge the batteries. Allow the batteries to rest 24 hours before performing this procedure
to allow the battery cells to equalize.
1.
2.
3.
4.
5.