background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Summary of Contents for PCI-PDISO8

Page 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Page 2: ...PCI PDISO8 Isolated Input and Relay Output Document Revision 10A April 2012 Copyright 2012 User s Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ...l by photocopying recording or otherwise without the prior written permission of Measurement Computing Corporation Notice Measurement Computing Corporation does not authorize any Measurement Computing Corporation product for use in life support systems and or devices without prior written consent from Measurement Computing Corporation Life support devices systems are devices or systems that a are ...

Page 4: ...Documentation 6 Optional components 6 Unpacking 6 Installing the software 6 Installing the hardware 6 Signal connections 7 P2 pinout 8 Cabling 8 Signal termination 9 Chapter 3 Functional Details 10 Relay outputs 10 Form C relay 10 Form A relay 10 Isolated inputs 11 Extending the input range 11 AC input filter 11 Mechanical drawing 12 Chapter 4 Specifications 13 Isolated inputs 13 Power consumption...

Page 5: ...and help topic titles and to emphasize a word or phrase Where to find more information Additional information about the PCI PDISO8 is available on our website at www mccdaq com You can also contact Measurement Computing Corporation by phone fax or email with specific questions Phone 508 946 5100 and follow the instructions for reaching Tech Support Fax 508 946 9500 to the attention of Tech Support...

Page 6: ...he inputs are not polarity sensitive and may be driven by either AC 50 1000 Hz or DC Each input channel has a programmable low pass filter with a time constant of 5 ms 200 Hz The eight outputs are electromechanical relays Five relays provide Form C connections and three relays provide normally open Form A connections The relays are controlled by writing to an eight bit port The relay control regis...

Page 7: ... PCI PDISO8 from its packaging ground yourself using a wrist strap or by simply touching the computer chassis or other grounded object to eliminate any stored static charge If any components are missing or damaged notify Measurement Computing Corporation immediately by phone fax or e mail Phone 508 946 5100 and follow the instructions for reaching Tech Support Fax 508 946 9500 to the attention of ...

Page 8: ...nt Computing Data Acquisition Software CD and click OK 3 To test your installation and configure your board run the InstaCal utility installed in the previous section Refer to the Quick Start Guide that came with your board for information on how to initially set up and load InstaCal Signal connections The table below lists the board connectors applicable cables and compatible accessory boards Boa...

Page 9: ... board connector Use extreme caution Never handle the PCI PDISO8 when signals are connected to the board through the connector P2 pinout Figure 3 P2 connector pinout Cabling Figure 4 C37FF x cable Figure 5 C37FFS x cable 20 1 37 19 20 1 37 19 The red stripe identifies pin 1 37 19 20 1 20 1 37 19 37 20 1 20 1 37 19 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisa...

Page 10: ...available on our web site at www mccdaq com products screw_terminal_bnc aspx Caution Do not use exposed screw terminal boards if your field voltage is more than 24 volts Using a screw terminal board with high voltage inputs or outputs exposes you and others to those high voltage signals Construct a safe cable to carry your signals directly from your equipment to the PCI PDISO8 connector Additional...

Page 11: ...mon and NO are in contact Form A relay The Form A relay has a common and a normally open NO contact Figure 7 shows the schematic for a Form A relay like those connected at relay 5 through relay 7 Figure 7 Form A Relay 5 contacts When 0 is written to the output the common and NO are NOT in contact When 1 is written to the output the common and NO are in contact The Form A and Form C relays on the P...

Page 12: ... information on digital signal connections and digital I O techniques refer to the Guide to Signal Connections This document is available on our web site at available on our web site at www mccdaq com signals signals pdf AC input filter The inputs are eight individual optically isolated 500 V inputs that can be read back as a single byte The inputs are not polarity sensitive and may be driven by e...

Page 13: ...PCI PDISO8 User s Guide Functional Details 12 Mechanical drawing Figure 10 PCI PDISO8 board dimensions Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 14: ...n contact to Common Isolated inputs Table 2 Isolated input specifications Number 8 Isolation 500 V Resistance 1 6 k Ohms min Voltage range DC 5 to 28 V Not TTL compatible AC 5 to 28 V 50 to 1000 Hz Input High level 5V min positive or negative input voltage not TTL compatible Input Low level 2 5V max positive or negative input voltage Response w o filter 20 µS w filter 5 mS Filters Time constant 5 ...

Page 15: ...Signal Name 1 Input 7A 20 Input 7B 2 Input 6A 21 Input 6B 3 Input 5A 22 Input 5B 4 Input 4A 23 Input 4B 5 Input 3A 24 Input 3B 6 Input 2A 25 Input 2B 7 Input 1A 26 Input 1B 8 Input 0A 27 Input 0B 9 Relay 7 C 28 Relay 7 NO 10 Relay 6 C 29 Relay 6 NO 11 Relay 5 C 30 Relay 5 NO 12 Relay 4 NC 31 Relay 4 C 13 Relay 4 NO 32 Relay 3 NC 14 Relay 3 C 33 Relay 3 NO 15 Relay 2 NC 34 Relay 2 C 16 Relay 2 NO 3...

Page 16: ...ic Discharge immunity EN61000 4 3 2002 Radiated Electromagnetic Field immunity EN61000 4 4 2004 Electric Fast Transient Burst immunity EN61000 4 5 2001 Surge immunity EN61000 4 6 2003 Radio Frequency Common Mode immunity EN61000 4 11 2004 Voltage Dip and Interrupt immunity Declaration of Conformity based on tests conducted by Chomerics Test Services Woburn MA 01801 USA in September 2001 Test recor...

Page 17: ...orporation 10 Commerce Way Suite 1008 Norton Massachusetts 02766 508 946 5100 Fax 508 946 9500 E mail info mccdaq com www mccdaq com Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 18: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...