6.2 Programming commands
6.2.1
Command Reference user level
Default after power on or software reset.
Commands in
user level
Input
Output
Comment
Stop continuous
output of
inclination values
“
s
”
“s”
Stops the continuous output of angle
results or raw values, required for
input of commands, terminated by “S”
or Reset or Power On,
mode temporary
Start continuous
output of values
“
S
”
“X=+01.234”, CR, LF,
“Y=-00.007”, CR, LF,
“X=……”
Starts the continuous output of angle
results or raw values,
mode temporary
Version and serial
number
“
V
”
“DPL2 V1.8.0”, CR, LF,
“SN:123456789”, CR, LF,
Output of SW-Version and serial
number, use in stopped mode only
Read one value
“
R
”
“X=+01.234”, CR, LF,
“Y=-00.007”, CR, LF,
Output of 1 complete string, 1 x-value
and 1 y-value, only in stopped mode
Activate setup
level
“
f
”
“
i
”
“
m
”
“
a
”
“f”
“i”
“m”
“a”
Activate the setup level, chapter
6.2.2. Setup level can be deactivated
by sending “K” or resetting with “q”.
The controller automatically exits this
level after about 10 minutes of user
inactivity with a reset.
any other no reaction
No reaction for commands from setup
level