Features
Wiring
Environmental limitations
Cautions
Settings and connections
1. Output Current Level Settings
‧
‧
‧
‧
‧
‧
‧
180~295VAC input only
Built-in active PFC
Output current level selectable by DIP switch
Built-in DALI interface and push dimming function (DA version)
Built-in 0~10Vdc and PWM signal dimming function (Non-DA version)
Power supply synchronization function up to 10 units
Temperature compensation function by external NTC
‧
‧
‧
‧
‧
‧
‧
Class power unit, ungrounded
Built-in 12V/50mA auxiliary output
Full plastic case enclosed
No load power consumption <1W (1.2W for DA version)
Protections: Short circuit / Over voltage / Over temperature
3 year warranty
Suitable for intelligent LED lighting
Ⅱ
‧
‧
‧
‧
Housing with cable clamp for remote installation
Use wires with an adequate cross-section (see 5)
Use suitable mounting tools to do the wiring and mounting (see 5)
MCB
circuit breaker) with an adequate current rating to protect the lighting system (see 6)
Use a
(miniature
‧
‧
‧
Maximum ambient temperature must not exceed 60
Always allow adequate ventilation clearances, 50mm, around the unit in use to prevent it from overheating
Only install the unit in interior environments
℃
‧
‧
This unit must be installed by a qualified electrician
This unit is not suitable for applications that DC/DC converters are connected before LED lamps
The LCM can provide various output currents by setting the DIP switch. The settings of the DIP switch are shown in the tables below.
LCM-40(DA)
LCM-60(DA)
Note : 1.Factory default setting is 700mA.
2.Output voltage and output wattage must not exceed the rated values.
Voltage
range
Voltage
range
1
1
2
2
3
3
4
4
5
5
6
6
Selectable
Current
Selectable
Current
2-100V
2-90V
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
350mA
500mA
2-80V
2-90V
500mA
600mA
2-67V
2-86V
600mA
700mA*
2-57V
2-67V
700mA*
900mA
2-45V
2-57V
900mA
1050mA
2-40V
2-42V
1050mA
1400mA
LCM-40(DA), LCM-60(DA) installation manual
ON
6 5 4 3 2 1
-Vo
+Vo
SYN.
+
-NTC
+DIM
-DIM
+NTC
-FAN
+FAN
+
DA-
DA+
PUSH
AC/N
AC/L
Terminal blocks assignment for LCM
2. Connection of LED Lamps
Press down the "push button" by a slotted screw driver to insert or remove the cable.
Vo-
Vo+
AC/N
AC/L
NEUTRAL (Blue or whit e)
LIVE (Brow n or black)
http://www.meanwell.com
123.5mm
23mm