D-Verter
User Guide, Rev: A/b
18 / 23
T
ECHNICAL
D
ATASHEET
E
LECTRICAL
R
EQUIREMENTS
If the supply cord is damaged, it must be replaced by a special cord or assembly available from
the manufacturer, or its distributing / service agent.
-
Operating voltage: 100-250 VAC, single phase. 50/60 Hz, 50 W.
-
Ground / Earth connection
REQUIRED
.
-
Cable Preparation
Da = 9.5 [0.374”] - 15.0 [0.59”]
-
Cable Assembly
1.
Put bushing and chuck onto the cable
2.
Prepare cable as shown above
3.
Insert the wire into the terminals and fasten the clamping device by a flat screw
driver
4.
Push insert and chuck into housing (pay attention to the guiding keyway!)
5.
Fasten bushing by means of a fork wrench ¾”, min. Torque 2.5 Nm (1.8 lb-ft)
C
ABLE
R
EQUIREMENTS
-
Power input:
1 mm (18 AWG), 3-wire, 90 ˚C copper,
CE UL/CSA compliant cable
-
DMX/RDM data: Dual twisted pair 0.75 mm (22 AWG) + shield, XLR-5 type connector,
CE UL/CSA compliant cable.