CSP−HMI−2
MD Helicopters, Inc
.
MAINTENANCE MANUAL
53−40−30
Page 209
Revision 39
(3). Wipe dry using a clean, lint−free, dry
cloth and allow to air dry for 15 min-
utes at ambient temperature.
Do not heat conduit to more
than 170
°
F (77
°
C). Conduit and
tailboom can be damaged from too much
heat.
(4). If conduit is bent away from tailboom,
heat conduit to make more flexible for
re−bonding.
NOTE:
Adhesive must be applied within 2
hours of preparation. If more than 2 hours
elapse before adhesive application, re−pre-
pare surfaces.
(5). Mix adhesive (CM402) according to
manufacturer’s instructions and apply
to faying surfaces.
(6). Secure parts together with light
pressure and allow to cure for 24 hours
at ambient temperature.
G53−4004A
APPLY
ADHESIVE
HERE
APPLY
ADHESIVE
HERE
APPLY
ADHESIVE
HERE
APPLY ADHESIVE HERE
SUPPORT
TAILBOOM
CONDUIT
SECTION B−B
38
°
28
′
SECTION A−A
LOOKING AFT
28
°
20
′
SECTION C−C
LOOKING FORWARD
BL
0.000
BL
0.000
B
B
A
A
C
C
FS 168.200
CANT
FS 263.916
CANT
500N TAILBOOM SHOWN
Figure 203. Conduit and Support Strap Rebonding
CAUTION