Theoretical notions for installation 

Technical service – MCZ GROUP S.p.A. all rights reserved - Reproduction prohibited 

 

  

IMPORTANT! 

 

The  fireplace  stove  must  be  installed  and 

assembled by qualified personnel. 

 

The  fireplace  stove  must  be  connected  to  a  flue 

pipe  or  other  vertical  smoke  stack  that  can 

discharge  smoke  at  the  highest  point  of  the 

house.  

 

The  fireplace  stove  must  be  connected  to  a  flue 

pipe  or  an  internal  or  external  vertical  duct 

conforming to current standards UNI 7129 - 7131 

9615. 

 

Smoke  is  generated  from  burning  wood  and, 

therefore, may dirty adjacent or nearby walls. 

 

Before  positioning  the  fireplace  stove,  you  must 
make a hole for the intake of external air. 

 

2.3.  

CONNECTION TO THE EXTERNAL AIR INTAKE 

The room where the stove is installed must have at least as much air as 

requested  by  normal  combustion  of  the  equipment  and  by  room 

ventilation.  This  may  take  place  through  permanent  apertures  in  the 

room walls that lead directly outdoors or ventilated rooms according to 

UNI 10683. 
For this purpose, drill a hole with minimum 360 cm² free section near 

the fireplace stove (22 cm diameter or a 20x18cm rectangle), protected 

by an indoor and outdoor grille. 
The air intake must also: 

 

directly communicate with the installation room 

 

be  protected  by  a  grill,  made  of  metallic  anti-insect  mesh  or  a 

suitable  protection  as  long  as  it  does  not  reduce  the  minimum 

section. 

 

be installed so as to avoid obstruction 

 

for ducts, up to 3.5 linear metres, increase the section by about 

5% while increased by 15% for larger measurements. 

 

 

Remember  that  the  ventilation  grills  always  have  a  cm

2

 

useful section on one side. When selecting the grill and hole 

dimension, make sure the useful grill section is greater than 

or  equal  to  the  section  required  by  MCZ  for  product 

operations. 
Connecting the air outlet directly to the fireplace stove is not 
mandatory but the above mentioned section must guarantee 

about 50 m³/h of air. See standard UNI 10683. 

 

  

IMPORTANT! 
Air flow may also be obtained from a room adjacent 

to  the  installation  room  as  long  as  this  flow  is  free 

through 

permanent 

apertures 

that 

directly 

communicate  with  the  outdoors;  avoid  air  outlets 

connecting  with  heating  units,  garages,  kitchens  or 

bathrooms. 

Summary of Contents for Forma Series

Page 1: ...INSTALLATION AND USE MANUAL EN...

Page 2: ...ATION AND ASSEMBLY 16 4 1 PREPARATION AND UNPACKING 16 4 2 POSITIONING 16 4 3 HEIGHT ADJUSTMENT 17 4 4 RELEASE OF COUNTERWEIGHTS 17 4 5 PLUMBING CONNECTION 18 4 5 1 Water characteristics 18 4 5 2 Hydr...

Page 3: ...TO BE PERFORMED BY THE USER 30 6 1 1 Cleaning the glass 30 6 1 2 Cleaning the exchanger 30 6 1 3 Cleaning out the ashes 30 6 1 4 Cleaning flue pipe 31 6 1 5 Lubrication and routine maintenance of the...

Page 4: ...out prior notice Reproduction even partial of this manual without the Manufacturer s authorisation is prohibited Manual preservation Please take care of this manual and keep it in a place that can be...

Page 5: ...ervision Only use the fuel recommended by MCZ The appliance must not be used as an incinerator The use of liquid fuel is strictly forbidden The instructions provided in this manual must always be comp...

Page 6: ...to the fireplace stove If the chimney flue draught is poor due to bad weather or improper installation start the fire decisively while keeping the door slightly ajar When you close the door keep the...

Page 7: ...aused directly or indirectly by persons animals or things as a result of the failure to observe all the provisions set forth in the instruction booklet especially those concerning warnings on the subj...

Page 8: ...ooms or rooms where fire hazards do not exist such as garages wood sheds flammable material warehouses strictly observing the provisions of current regulations Fireplace stoves may not be installed in...

Page 9: ...ding to UNI 10683 For this purpose drill a hole with minimum 360 cm free section near the fireplace stove 22 cm diameter or a 20x18cm rectangle protected by an indoor and outdoor grille The air intake...

Page 10: ...are used they must be insulated with suitable material such as ceramic fibre matting to avoid deterioration of the masonry and of the decorative hood liner IMPORTANT Any increase in the section of the...

Page 11: ...uitably sized in accordance with EN13384 1 The smoke duct should be equipped with a solid material collection chamber at the mouth of the smoke duct to be easily opened with an airtight door IMPORTANT...

Page 12: ...lt to prevent rain snow and any foreign objects from getting into the flue pipe They must be installed to guarantee adequate smoke dispersion and out of the reflux area where negative pressure forms F...

Page 13: ...072 kcal h Efficiency 77 1 Heatable volume m3 563 40 644 35 751 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 333 C Smoke outlet 25 cm Net weight 232 kg Hydrotherm 80 235 Kg Hydrotherm 80E...

Page 14: ...me m3 456 40 521 35 608 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 310 C Smoke outlet 20 cm Net weight 195 kg Hydrotherm 70 212 Kg Hydrotherm 70V External combustion air inlet cm 150 CO...

Page 15: ...ut power H2O 13 0 kW 11 180 kcal h Efficiency 75 2 Heatable volume m3 456 40 521 35 608 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 310 C Smoke outlet 20 cm Net weight 204 kg External com...

Page 16: ...taking care that its position complies with the above instructions The fireplace stove must always be kept VERTICAL while moving and only using hand trucks Do not drag the unit as this may damage the...

Page 17: ...y pedestal to set the product on Do not eliminate the feet They are indispensable for levelling If the fireplace stove is not placed level there is the risk that door will not close perfectly and that...

Page 18: ...of hard water being used it is advisable to install a softener filter 4 5 1 Water characteristics The characteristics of the water used to fill the system are very important to prevent the build up of...

Page 19: ...tank must feature no shut off valve or unneeded curves Both the open expansion tank and the vent tube must be protected against the cold 4 5 3 Hydraulic connection with Closed Tank In order to achieve...

Page 20: ...accessory This is a device that limits the water temperature In case of boiler overheating it activates an emergency exchanger that causes the immediate cooling of the water Its use is regulated by th...

Page 21: ...sons any cut off valves placed upstream of the valve must be open You should install a pressure reducer at the inlet of water from the water mains The reducer must be calibrated at 2 bars at least and...

Page 22: ...is located that lets you perform the purging operations and check the function It is necessary for a technician check the function of the valve at least once a year 4 7 5 Safety MCZ SHALL NOT BE HELD...

Page 23: ...raulic connections pay attention not to mechanically over stress the thread of the valve body In time it is possible that breakages may occur with hydraulic leaks damaging people and or objects A wate...

Page 24: ...damaged or catch fire walls made of wood plasterboard etc 4 8 2 INSULATING A WOODEN BEAM The wood beam must be protected with adequate insulation from heated parts to prevent the risk of fire or damag...

Page 25: ...not stay near the fireplace stove and as previously mentioned ventilate the room The smoke and the smell of paint will vanish after about one hour of operation There are no health risks involved The...

Page 26: ...r after a lighting at full power has occurred a few times Make sure you have read and completely understood the contents of this instruction booklet Remove any components which might burn from the fir...

Page 27: ...or polluting substances Do not burn rubbish The gases produced by combustion due the use of unsuitable fuels cause damage to the fireplace stove and the chimney they cause pollution and can compromise...

Page 28: ...al that can dirty glass faster Also the low performance of the flue pipe can jeopardise glass cleanliness since smoke remains in the combustion chamber longer than normal 5 6 FIRST LIGHTING It is advi...

Page 29: ...be cleaned During use the metal parts and the glass reach high temperatures For all jobs of loading the stove adjustment or cleaning the ash drawer use the insulating glove provided Never leave childr...

Page 30: ...1 2 Cleaning the exchanger A scraper is provided to remove the creosote that may form in the exchanger when the fireplace stove is cold the creosote is black shiny flaky and easy to remove The advice...

Page 31: ...ase both runners as follows Pull open the frame liner and extract the door so you can see the tracks of the guide Using the provided grease gun apply two drops of grease about 5 mm in diameter at the...

Page 32: ...AL WEIGHT KIT 7 1 Supplementary weight kits for door closure only available for closed tank version A supplementary weight kit is available as an accessory to be fixed above the door with this system...

Page 33: ...MCZ GROUP S p A Via La Croce 8 33074 Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 599599 PBX Fax 39 0434 599598 Internet www mcz it e mail mcz mcz it 8901158500 Rev 1 01 2016...