Before Starting Equipment Make Certain That:
1. The correct voltage has been supplied to the equipment.

2. The electrical plug from the control box has been inserted

into the receptacle.

During Start-up (Applies only to standard equipment)
1. Set the ventilation damper to the OPEN or CLOSED

position as required by the owner.

2. Push the HIGH button to select the fan speed; push the

HEAT button. Move the thermostat control to the extreme
heating position (counterclockwise). Heat should cycle on
and off as the thermostat requires. Push the LOW button;
the fan should change to the lower speed.

One-Year Warranty of Entire Conditioner— McQuay Inter-
national, hereinafter referred to as the “Company,” warrants
to the original owner that the entire Incremental Comfort
Conditioner is free from defects in material and workman-
ship. Any part or portion thereof which becomes defective
under normal use during the period of this warranty will be
repaired or replaced provided the Company’s examination
shall prove to its satisfaction that the part was or became
defective under normal use. This warranty contemplates that
first year maintenance labor was arranged for with the
installer or otherwise at the time the conditioner was pur-
chased or installed. The Company’s obligations under this
warranty are limited to: (a) Repairing the defective part or (b)
Furnishing a replacement part provided the defective part is
returned to the factory, transportation charges prepaid. No
reimbursement will be made for expenses incurred in making
field adjustments or replacements unless specifically autho-
rized in writing by the Company.

This warranty constitutes the buyer’s sole remedy. It

is given in lieu of all other warranties. There is no implied
warranty of merchantability or fitness for a particular
purpose. In no event and under no circumstance shall the
Company be liable for incidental or consequential dam-
ages, whether the theory be breach of this or any other
warranty, negligence, or strict tort.

No person (including any agent, salesman, dealer or

distributor) has  authority to expand the Company’s obliga-
tion beyond the terms of this express warranty, or to state
that the performance of the product is other than that
published by the Company.

One Year Refrigeration Circuit Warranty — Hermetically
sealed motor-compressor assemblies and all components

of refrigeration circuits not readily separable therefrom are
warranted to the original owner for one year. Refrigerating
circuits consist of the motor-compressor assembly evapora-
tor coil, condenser coil and interconnecting tubing. Repairs
under this warranty will be made at the Company’s expense
provided that the refrigerating circuit is delivered without
shipping damage, transportation prepaid to the factory or to
a factory designated repair station, at the Company’s option.
This one-year warranty does not include any other parts of
the equipment such as filters, fans, fan motors, controls,
cabinet parts, electrical relays, capacitors, protective de-
vices, or wiring. The Company is not obligated under this
warranty for field labor such as service for inspection, remov-
ing, packing and/or reinstalling the refrigeration circuit, nor
for return transportation charges.

General Conditions — The above warranties are void if the
Company’s equipment has been damaged, misused, sub-
jected to abnormal use or service or its serial number has
been altered, defaced or removed, or payment for the equip-
ment is in default. The Company is not responsible for
service to correct conditions due to misapplication, im-
proper installation, inadequate wiring, incorrect voltage con-
ditions or unauthorized opening of the refrigeration circuit,
nor for consequential damages. In case the Company’s
equipment is installed in conjunction with cabinets, grilles,
louvers, controls or other parts manufactured by others,
these warranties shall apply only to the Company manufac-
tured portion of the equipment. The conditions of the war-
ranty plan are effective for eighteen (18)  months from date of
factory shipment. The Company reserves the right to make
a handling and inspection charge in the case of parts or
equipment improperly returned as defective and/or as being
in warranty.

3. Push the HIGH button to select the fan speed; push the

COOL button. Move the thermostat control to the extreme
cooling position (clockwise). The compressor should cycle
on and off as the thermostat requires. Push the LOW
button; the fan should change to the lower speed.

4. Push the OFF or STBY button. The fan should stop and

neither the heater nor the compressor should continue to
operate.

Note: The direction of the conditioned air may be adjusted by
rotation of discharge grilles to change airflow pattern in a
room. The building superintendent or manager should be
requested to make any changes, as a thin flat-edged tool is
required to move grille.

Installation, Service & Warranty Policy

P

rinted on recycled paper containing at least 10% post-consumer recycled material.

13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 USA

(612) 553-5330

Summary of Contents for Incremental MQT Series

Page 1: ...uh cooling 09 Nominal 9 000 Btuh cooling 11 Nominal 11 000 Btuh cooling 14 Nominal 14 000 Btuh cooling Vintage Designation B Sizes 06 09 11 C Size 14 Unit Type A Air conditioner with electric heat B Air conditioner with hydronic heat C Heat pump with supplemental electric heat MQT 09 B C 5 B Heater Code A 2 0 kW electric heat B 3 2 kW electric heat C 4 8 kW electric heat G Steam heat W Hot water h...

Page 2: ...onal 3 8 10mm Louver Stamped Standard or 11 8 29mm Louver Extruded Optional 1 2 3 3 1 Note 4 minimum space requirement between underside of unit and floor for return air Subbase is optional on 208 and 230 volt units but standard on 265 volt A 3 4 19mm drip lip Optional condensate connection Figure 2 Conditioner wall mounted 93 4 248mm Min 4 102mm Min 2 x 4 51 x 102mm Junction Box All wiring should...

Page 3: ... provided in the basepan of the wall sleeve for this purpose Optional Subbase Whenever a subbase is used it must be installed prior to the room cabinet wall sleeve The subbase provided in four pieces is adjustable from 43 8 to 155 8 111 to 397mm in depth to accommodate various projections of the conditioner into the room The standard subbase height is 4 102mm with adjustable leveling bolts to 41 2...

Page 4: ...r building surface 3 Secure the louver frame to the wall through the sides and top of the sleeve Never secure the louver frame through the bottom Note The louver frame may also be secured from inside the room cabinet wall sleeve by screws driven through the sides and top of the louver frame sleeve Pre Installation Conditioner Preparation 1 Remove the outer carton of the room cabinet wall sleeve ch...

Page 5: ... wall opening by the depth of the louver to be installed see Figure 8 The center of gravity of the conditioner is 91 2 241mm from the rear face For wall mounted conditioners the center of gravity must be within the load bearing portion of the wall otherwise some method of support is required 3a Installations without a subbase Level or pitch the room cabinet wall sleeve a maximum of1 8 3mm down war...

Page 6: ...e assembly is 1 2 nominal copper tubing 5 8 O D actual The easiest method of connection would be with a short length of 5 8 I D flexible PVC tubing having a wall thickness of at least 1 8 3mm to prevent kinking or collapse however follow all local applicable codes Heating Cooling Chassis Installation 1 Slide the chassis into the room cabinet wall sleeve until firmly seated against the weather seal...

Page 7: ...losed exerting sufficient pressure on the top black border area to allow the latching buttons to snap into place usually with an audible click 6 Replace the two sheetmetal screws adjacent to the latch ing buttons in the front panel 7 Replace the filter assembly at the bottom of the front panel Initial start up of the Incremental conditioners by an experi enced technician is usually the responsibil...

Page 8: ...he original owner for one year Refrigerating circuits consist of the motor compressor assembly evapora tor coil condenser coil and interconnecting tubing Repairs under this warranty will be made at the Company s expense provided that the refrigerating circuit is delivered without shipping damage transportation prepaid to the factory or to a factory designated repair station at the Company s option...

Reviews: