McPhiben CTX Series Instruction Manual Download Page 1

CEILING MTG

SCREW HOLES

FRONT COVER ASSY

TRANSFORMER

TRANSFORMER

OUTPUT CABLE

BATTERY

MAIN PCA

ELECTRONICS

OPERATOR PANEL

BATTERY

STRAP

LAMP

CABLE

BACK-PLATE ASSY

IMPORTANT SAFEGUARDS

SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

+

Do not use outdoors.

+

Do not mount near gas or electric heaters.

+

Do not let power supply wires touch hot surfaces.

+

Equipment should be mounted in locations and at heights where it will not readily be subjected 

to tampering by unauthorized personnel.

+

The use of accessory equipment not authorized by the manufacturer may cause an unsafe 

condition.

+

Do not use this equipment for other than its intended purpose.

+

Service of this equipment should be performed by qualified service personnel.

+

No rigid conduit.

Flexible conduit only

No rigid conduit

THERMOPLASTIC EMERGENCY

LIGHTING PRODUCTS

mcPhilben

CTX Series

INSTRUCTION MANUAL

p/n: 787625460

T 1    Std Local Lamps Only
T 2    Local & Remote-A Lamps

Options

TD     Re-strike TimeDelay
RC    Remote Control

Circuit Assembly Code

Self-Testing / Self-Dianostic

X

X

test

Summary of Contents for CTX Series

Page 1: ...ere it will not readily be subjected to tampering by unauthorized personnel The use of accessory equipment not authorized by the manufacturer may cause an unsafe condition Do not use this equipment for other than its intended purpose Service of this equipment should be performed by qualified service personnel No rigid conduit Flexible conduit only No rigid conduit THERMOPLASTIC EMERGENCY LIGHTING ...

Page 2: ...THE CEILING SURFACE WITH SUITABLE HARDWARE to prevent sag and or the unit falling Route the proper two transformer input wires BLACK 120V WHITE common RED 277V out through the hole in the back plate make input connection and secure back plate to the ceiling surface box Verify the battery is connected to the main PCA and connect the small transformer cable Replace snap the unit closed and check sec...

Page 3: ... Sequence The unit automatically performs diag testing at all power up and initializes itself The system is capable of instantaneously detecting lamp failures and is indicated by a flashing LAMP LED The system also constantly monitors and controls all functions the charging circuit the battery the input power level the EXIT LED s and operator manual tests The charge circuit is computer controlled ...

Page 4: ...test 1 Press performs a 5 sec brief test all lamps operating from battery only 2 Presses performs a 1 min test all lamps operating from battery only 3 Presses performs a 30 min discharge test all lamps operating from battery only The system allows only one 30 min test each 24 hr period CONTINUOS MONITORING The system monitors the battery for proper levels and performs periodic low level charger an...

Reviews: