![MC Electronics GLM KIT Instructions For Use Manual Download Page 11](http://html1.mh-extra.com/html/mc-electronics/glm-kit/glm-kit_instructions-for-use-manual_1753067011.webp)
Instructions for use
GLM KIT
11
3.2.2
"RPM" sensor installation
The inductive sensor to detect turbine RPM must be positioned in front of metal references
with a diameter at least equal to the corresponding sensor and protruding from any other
metal mass by at least 7mm. The distance between the sensor and its metal reference
varies from 2 to 3mm.
The figures below show two different installation examples.
Figure 6 - Installation of the inductive sensor D.18 on the PTO.
Figure 7 - Installation of the inductive sensor D.12 on the gearbox.
!
Warning
The sensor cable should be covered with a rubber sheath.
Bolt
Bushing
RPM sensor
RPM sensor
Bushing
Bolt
2-3 mm
PTO connection
2mm
1.2mm
E.g.: Gearbox
Inductive sensor