22
Assembly
Acceptance test (in case of industrial/public use):
Before first use and after any significant modifications, the installation (including the electrical
connections) must be inspected by an official expert.
A yearly inspection by an expert is required.
At least every 4 years, an acceptance test must be carried out by an expert.
• Attach the included mounting bracket to the casing with the lateral thumbscrews.
• Install the effect beamer on the ceiling, the wall or a suitable crossbeam with the mounting bracket. The assembly
must never swing freely.
• Secure the device with assembly equipment that is compatible with the attachment surface and suitable for
carrying the weight of the effect light.
• Also secure the installation with a suitable safety restraint cable or a safety net to be hooked into the ring screw
at the casing. The safety retention rope or the net must be designed to support the effect light in the event of failure
of the main support system independently of the main attachment.
• Set the desired inclination angle and tighten the thumb screws well.