Fig. 6: Identifying Generator Lower Bolt
Courtesy of MAZDA MOTORS CORP.
GENERATOR REMOVAL NOTE
1. Remove the generator from above the engine compartment.
GENERATOR INSTALLATION NOTE
1. Tighten the upper and lower bolts temporarily.
2. Tighten the upper bolt to the specified tightening torque.
3. Tighten the lower bolt to the specified tightening torque.
GENERATOR INSPECTION [MZI-3.5]
GENERATOR WARNING LIGHT
1. Verify that the battery is fully charged.
2. Verify that the generator and A/C drive belt deflection/tension is correct. (see
DRIVE BELT
INSPECTION [MZI-3.5]
.)
3. With the ignition switch turned to the ON position, verify that the generator warning light illuminates.
z
If it does not illuminate, inspect the generator warning light and the wiring harness.
If the generator warning light and the wiring harness are normal, inspect the PCM.
4. Verify that the generator warning light goes out after the engine is started.
z
If it does not go out, inspect if any DTCs are displayed.
If any DTCs are displayed, carry out troubleshooting according to the corresponding DTC
inspection.
GENERATOR
Voltage
1. Verify that the battery is fully charged.
2. Verify that the generator and A/C drive belt deflection/tension is correct. (see
DRIVE BELT
2007 Mazda CX-9 Grand Touring