Maytag MGD6000XG Installation Instructions Manual Download Page 1

W10057364B

W10310421B - SP

GAS DRYER INSTALLATION INSTRUCTIONS

CANADIAN ELECTRIC DRYER INSTRUCTIONS

INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE 

À GAZ (É.-U. ET CANADA)

ÉLECTRIQUE (CANADA UNIQUEMENT)

Table of Contents 

DRYER SAFETY ................................................................2

INSTALLATION REQUIREMENTS ....................................4

 

 

Tools and Parts ...................................................................... 4

LOcATION REQUIREMENTS ..................................................... 5
ELEcTRIc DRYER POWER HOOkUP-cANADA ONLY ........... 6
GAS DRYER POWER HOOkUP ................................................. 7
INSTALL LEvELING LEGS .......................................................... 9
MAkE GAS cONNEcTION ......................................................... 9
vENTING .................................................................................... 10 

  venting Requirements ......................................................... 10

 

 

Plan vent System ................................................................. 12 

 

Install vent System .............................................................. 11

cONNEcT INLET HOSE ........................................................... 12
cONNEcT vENT ....................................................................... 14 
LEvEL DRYER ........................................................................... 14
cOMPLETE INSTALLATION cHEckLIST ............................... 15
DOOR REvERSAL (OPTIONAL) ............................................... 16

INSTALLATION NOTES

Date of purchase:

 _________________________________

Date of installation:

  _______________________________

Installer:

 ________________________________________

Model number:

 ___________________________________

Serial number:

 ___________________________________

Date d’achat:

 ______________________________________

Date d’installation:

 __________________________________

Installateur:

 _______________________________________

Numéro de modéle:

 _________________________________

Numéro de série:

 ___________________________________

NOTES cONcERNANT L’INSTALLATION

Para una version de estas instrucciones en español, visite www.Whirlpool.com

Table des matières

SÉcURITÉ DE LA SÉcHEUSE ....................................... 19

EXIGENcES D’INSTALLATION ...................................... 21

 

 

Outillage et pièces .............................................................21

 

EXIGENcES D’EMPLAcEMENT ...............................................22
SÉcHEUSE ÉLEcTRIQUE RAccORDEMENT à 

L’ALIMENTATION ÉLEcTRIQUE - cANADA SEULEMENT .....24
RAccORDEMENT D’UNE SÉcHEUSE à GAz ........................25
INSTALLATION DES PIEDS DE NIvELLEMENT ......................27
INSTRUcTIONS POUR LE RAccORDEMENT AU GAz .........27
SYSTÈME D’ÉvAcUATION........................................................28 

 

Exigences concernant l’évacuation .................................28

 

 

Planification du système d’évacuation ............................29

 

 

Installation du système d’évacuation ...............................30

RAccORDEMENT DES TUYAUX D’ALIMENTATION ..............31
RAccORDEMENT DU cONDUIT D’ÉvAcUATION .................34
RÉGLAGE DE L’APLOMB DE LA SÉcHEUSE..........................34
AcHEvER L’INSTALLATION LISTE DE vÉRIFIcATION ...........35

I

NvERSION DE LA PORTE (FAcULTATIF) ................................35

Summary of Contents for MGD6000XG

Page 1: ...___________________ Date d achat _______________________________________ Date d installation ___________________________________ Installateur ________________________________________ Num ro de mod le...

Page 2: ...2 DRYER SAFETY...

Page 3: ...3 IMPORTANT When discarding or storing your old clothes dryer remove the door...

Page 4: ...ble wrench for gas connections Pipe joint compound resistant to LP gas Utility knife Y connector Short inlet hose Long inlet hose Rubber washers Min 8 long Torx T25 screwdriver for door reversal only...

Page 5: ...ored in an area where it will be exposed to water and or weather IMPORTANT Do not operate install or store dryer where it will be exposed to water weather or at temperatures below 40 F 4 C Lower tempe...

Page 6: ...responsibility To contact a qualified electrical installer To be sure that the electrical connection is adequate and in conformance with Canadian Electrical Code C22 1 latest edition and all local co...

Page 7: ...Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug provided with the dryer if it will not...

Page 8: ...f valve In the U S A An individual manual shut off valve must be installed within six 6 ft 1 8 m of the dryer in accordance with the National Fuel Gas Code ANSI Z223 1 The location should be easy to r...

Page 9: ...ply line valve is open when handle is parallel to gas pipe Then test all connections by brushing on an approved noncorrosive leak detection solution Bubbles will show a leak Correct any leak found A C...

Page 10: ...th of flexible metal vent used must be included in the overall vent system design as shown in the Vent System Chart NOTE If using an existing vent system clean lint from entire length of the system an...

Page 11: ...utside Determine vent path Select route that will provide straightest and most direct path outdoors Plan installation to use fewest number of elbows and turns When using elbows or making turns allow a...

Page 12: ...y to the cold water faucet the short hose must be used See figure B Attach short hose to cold water faucet Screw on coupling by hand until it is seated on faucet Then attach Y connector to male end of...

Page 13: ...ng pliers tighten the couplings an additional two thirds turn NOTE Do not overtighten Damage to the coupling can result 5 Attach long hose to dryer fill valve and tighten coupling Remove protective ca...

Page 14: ...k NOTE The dryer must be level for the moisture sensing system to operate correctly Connect vent 1 Connect vent to exhaust outlet 2 Move dryer to final location Using a 4 102 mm clamp connect vent to...

Page 15: ...buildup of lime scale may clog different parts of the water system which will reduce product performance Excessive scale buildup may lead to the need for certain part replacement or repair Electric Mo...

Page 16: ...he door strike to the door frame of the dryer Rotate the strike 180 and attach to the opposite side of dryer door frame as shown 3 Remove inner door from outer door Position the door with the inside o...

Page 17: ...removed earlier B 4 Remove outer window assembly from trim ring Using a Phillips screwdriver remove the 2 screws from the outer window retainer and rotate the outer window assembly clockwise until th...

Page 18: ...tches on the outer window assembly with the tabs on the trim ring and lower into place as shown in figure A Rotate the outer window assembly counterclockwise to lock tabs into place figure B Using a P...

Page 19: ...10 screws securing the inner door to the outer door 10 Reinstall door on dryer Using a Torx T25 screwdriver remove the 4 screws on the dryer Insert the tabs on the hinge into the mounting slot and sl...

Page 20: ...20 S curit de la s cheuse...

Page 21: ...21...

Page 22: ...on d un nouveau conduit Pistolet calfeutrage et compos de calfeutrage pour l installation d un nouveau conduit d vacuation Tourne crou de 1 4 et 5 16 recommand Couteau Tournevis Torx T25 de 8 20 cm mi...

Page 23: ...ension pour s cheuse pi ce n 279810 Si la s cheuse n est pas d aplomb le linge peut ne pas culbuter convenablement et les programmes automatiques command s par d tecteur peuvent ne pas fonctionner cor...

Page 24: ...ir en haut et en bas de la porte Les portes claire voie offrant des ouvertures quivalentes de passage de l air sont acceptables Il faut aussi prendre en compte l espace requis entre les appareils vois...

Page 25: ...il est recommand d utiliser le cordon d alimentation de rechange pi ce n 8529008 Pour plus de renseignements consulter les num ros de service indiqu s la section Assistance ou service du Guide d utili...

Page 26: ...doute quant la qualit de liaison la terre de la s cheuse consulter un lectricien ou un technicien ou un personnel qualifi Ne pas modifier la fiche de branchement fournie avec la s cheuse si la fiche n...

Page 27: ...atteindre pour ouvrir et fermer la s cheuse Au Canada Un robinet d arr t individuel manuel doit tre install conform ment la norme B149 1 du Code des installations au gaz naturel ou propane On recomman...

Page 28: ...pieds de nivellement diamond marking A B Connecter l alimentation en gaz la s cheuse 1 Retirer le capuchon rouge de la canalisation d arriv e de gaz l aide d une cl pour serrer raccorder l alimentatio...

Page 29: ...nt final de la s cheuse Enlever tout exc s de conduit pour viter tout affaissement et d formation susceptible de r duire la capacit d vacuation et le rendement Ne pas installer le conduit dans les cav...

Page 30: ...l humidit aux boiseries meubles peinture papier peint tapis etc Probl mes de nettoyage dans la maison et probl mes de sant Bon Meilleur Planification du syst me d vacuation Choisir un type de syst me...

Page 31: ...n ci dessous pour d terminer le type de composants et les combinaisons acceptables REMARQUE Ne pas utiliser un conduit de longueur sup rieure la valeur sp cifi e dans le tableau des syst mes d vacuati...

Page 32: ...r le raccord en Y l extr mit m le du tuyau court Visser compl tement le raccord la main pour qu il soit scell au connecteur en Y A 1 Fermer l eau froide retirer et remplacer le joint de caoutchouc Arr...

Page 33: ...compl tement le raccord la main pour qu il soit scell au raccord du robinet de remplissage Terminer le serrage des raccords deux tiers de tour suppl mentaires avec une pince REMARQUE Ne pas serrer ex...

Page 34: ...e la s cheuse ne tangue pas Placer le niveau ici Raccordement du conduit d vacuation Raccorder le conduit d vacuation la bouche d vacuation 1 D placer la s cheuse son emplacement final 2 l aide d une...

Page 35: ...ouverte q V rifier qu il n y a pas de fuites q V rifier que la canalisation de gaz souple n est pas cras e ou d form e Tous les mod les q S lectionner un programme de s chage minut avec chaleur et me...

Page 36: ...10 vis fixant la porte interne la porte externe Soulever la porte interne pour la d gager et la mettre de c t 4 Retirer la garniture circulaire de la partie externe du hublot l aide d un tournevis Ph...

Page 37: ...xterne du hublot et la r installer sur la garniture circulaire Tout en pla ant le bord comportant les 2 indentations au sommet aligner les indentations de la partie externe du hublot avec les onglets...

Page 38: ...rieur Fixer avec les 4 vis Torx T25 pr c demment retir es 7 Retirer la charni re et le loquet l aide d un tournevis Torx T25 retirer les 3 vis Torx fixant la plaque de protection du loquet et la plaqu...

Page 39: ...39...

Page 40: ...W10057364B W10310421B SP 2010 11 10 All rights reserved Printed in U S A Tous droits r serv s Imprim aux E U...