background image

17

PERFORMANCE DATA SHEETS

Interior Water Filtration System 

Model UKF8001AXX-750 Capacity 750 Gallons (2839 Liters)

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The 

concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the 

permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction 
Aesthetic Effects

NSF 
Reduction 
Requirements

Average 
Influent

Influent Challenge 
Concentration

Maximum 
Effluent

Average 
Effluent

Minimum% 
Reduction

Average% 
Reduction

Chlorine Taste/Odor 

Particulate Class I*

50% reduction 

85% reduction

2.00 mg/L 

14,000,000 #/mL

2.0 mg/L ± 10%  

At least  

10,000 particles/mL

0.06 mg/L 

370,000 #/mL**

0.050625 mg/L 

196,666 #/mL

97.00% 

97.40%

97.52% 

99.00%

Contaminant 
Reduction

NSF Reduction 
Requirements

Average 
Influent

Influent Challenge 
Concentration

Maximum 
Effluent

Average 
Effluent

Minimum% 
Reduction

Average% 
Reduction

Lead: @ pH 6.5  

Lead: @ pH 8.5

0.010 mg/L 

0.010 mg/L

0.150 mg/L

 

0.150 mg/L

0.15 mg/L ± 10% 

0.15 mg/L ± 10%

< 0.001 mg/L 

< 0.001 mg/L

< 0.001 mg/L 

< 0.001 mg/L

>99.30% 

>99.30%

>99.30% 

>99.30%

Mercury: @ pH 6.5 

Mercury: @ pH 8.5

0.002 mg/L 

0.002 mg/L

0.006 mg/L 

0.0059 mg/L

0.006 mg/L ± 10% 

0.006 mg/L ± 10%

0.0005 mg/L 

0.0018 mg/L

0.0003 mg/L 

0.00073 mg/L

91.70% 

69.20%

95.00% 

88.10%

Benzene

0.005 mg/L

0.0133 mg/L

0.015 mg/L ± 10%

0.0005 mg/L

0.0005 mg/L

96.10%

96.30%

p-Dichlorobenzene

0.075 mg/L

0.210 mg/L

0.225 mg/L ± 10%

< 0.0005 mg/L

< 0.0005 mg/L

>99.80%

>99.80%

Carbofuran

0.040 mg/L

0.0753 mg/L

0.08 mg/L ± 10%

0.027 mg/L

0.008 mg/L

64.60%

73.45%

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 ± 10%

< 0.001 mg/L

< 0.001 mg/L

>93.3%

>93.3%

Atrazine

0.003 mg/L

0.0102 mg/L

0.009 mg/L ± 10%

0.0027 mg/L

0.00105 mg/L

76.30%

89.40%

Asbestos

>99%

126.5 MF/L

10

7

 to 10

8

 fibers/L

††

< 0.17 MF/L

< 0.17 MF/L

>99.99%

>99.99%

Live Cysts

 ‡

 

Turbidity

>99.95%  

0.5 NTU

122,500 #/L 

10.5 NTU

50,000/L min. 

11 ± 1 NTU

< 1 #/L

 

0.30 NTU

< 1 #/L

 

0.125 NTU

>99.99% 

97.30%

>99.99% 

98.80%

Lindane

0.0002 mg/L

0.0019 mg/L

0.002 ± 10%

< 0.00016 mg/L

0.000035 mg/L

91.80%

97.90%

Tetrachloroethylene

0.005 mg/L

0.015 mg/L

0.015 mg/L ± 10%

< 0.0005 mg/L

< 0.0005 mg/L

>96.6%

>96.6%

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F ± 5°F (20°C ± 3°C).

 

It is essential that operational, maintenance, and filter replacement 

requirements be carried out for the product to perform as advertised.

 

The disposable water filter should be replaced at least every 6 

months.

 

The filter monitor system measures the amount of water that passes 

through the filter and alerts you to replace the filter. When 90% of 

the filter’s rated life is used, the yellow (Order) light comes on. When 

100% of the filter’s rated life is used, the red (Replace) light comes 

on, and it is recommended that you replace the filter. For models 

without filter status lights, replace the filter every 6 months. Use 

replacement filter model UKF8001. 2014 suggested retail price of 

$44.99U.S.A./$49.95 Canada. Prices are subject to change without 

notice.

 

The product is for cold water use only.

 

Do not use with water that is microbiologically unsafe or of unknown 

quality without adequate disinfection before or after the system. 

Systems certified for cyst reduction may be used on disinfected 

waters that may contain filterable cysts.

 

Refer to the “Water Filtration System” section for the Manufacturer’s 

name and telephone number.

 

Refer to the “Warranty” section for the Manufacturer’s limited 
warranty.

Application Guidelines/Water Supply Parameters

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.78 gpm (2.9 L/min.) @ 60 psi*

System tested and certified by NSF International against NSF/ANSI Standard 42 for the 

reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI 

Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, p-Dichlorobenzene, 

Carbofuran, Toxaphene, Cysts, Turbidity, Asbestos, Tetrachloroethylene and Lindane.

*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust

† 

These contaminants are not necessarily in your water supply. Performance may vary based on local water 

 

conditions.

†† 

Fibers greater than 10 um in length

‡ Based on the use of Cryptosporidium parvum oocysts

®

 NSF is a registered trademark of NSF International.

Summary of Contents for MFI2269FRW01

Page 1: ...and Water 15 PERFORMANCE DATA SHEETS 17 WARRANTY 19 NOTES 59 S CURIT DU R FRIG RATEUR 20 INSTRUCTIONS D INSTALLATION 22 D ballage du r frig rateur 22 Exigences d emplacement 23 Sp cifications lectriq...

Page 2: ...ner Do not store or use petrol flammable liquids or gas in the vicinity of this or other electrical appliances The fumes can cause fires or explosions Do not store explosive substances such as aerosol...

Page 3: ...cleaning instructions in Refrigerator Care WARNING Suffocation Hazard Remove doors from your old refrigerator Failure to do so can result in death or brain damage Important information to know about d...

Page 4: ...ave the proper electrical connection If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person Do not use a cord that shows cracks or a...

Page 5: ...al codes and ordinances The gray water tubing on the back of the refrigerator which is used to connect to the household water line is a PEX cross linked polyethylene tube Copper and PEX tubing connect...

Page 6: ...grounded 3 prong outlet NOTE Allow 24 hours to produce the first batch of ice Discard the first three batches of ice produced Allow 3 days to completely fill the ice container Refrigerator Doors and...

Page 7: ...ges are being moved Do not depend on the door gasket magnets to hold the door in place while you are working 3 Align the door so that the bottom of the refrigerator door aligns evenly with the top of...

Page 8: ...Removal Drawer Front Replacement A Loosen 4 Drawer Bracket Screws A Wiring Plug B Water Line Connection A Hinge Pin Cover B Bottom Hinge C Hinge Screws A Hinge Cover Screw B Top Hinge Cover C 5 16 Hex...

Page 9: ...nets furniture or trim If adjacent furnishings are not level it may not be possible to achieve even gaps when product is level 4 Open the door again to make sure that it closes as easily as you like I...

Page 10: ...werCold Feature The PowerCold feature assists with periods of high refrigerator use full grocery loads or temporarily warm room temperatures Press the POWERCOLD touch pad to set the freezer and refrig...

Page 11: ...f the refrigerator compartment Turning the Ice Maker On Off The On Off switch is located on the ice maker To turn on the ice maker press the switch to the ON position To manually turn off the ice make...

Page 12: ...ight will illuminate On For continuous light press the LIGHT button a second time The On indicator light will illuminate Off To turn the dispenser light off press the LIGHT button a third time Dispens...

Page 13: ...plastic part with a sponge and mild detergent in warm water Dry thoroughly with a soft cloth 4 There is no need for routine condenser cleaning in normal home operating environments If the environment...

Page 14: ...n longer if the room is warm a large food load is added doors are opened often or if the doors have been left open The refrigerator seems noisy Refrigerator noise has been reduced over the years Due t...

Page 15: ...es are hollow or small NOTE This is an indication of low water pressure Water shutoff valve not fully open Turn the water shutoff valve fully open Kink in the water source line A kink in the line can...

Page 16: ...r system See Water and Ice Dispensers Water from the dispenser is warm NOTE Water from the dispenser is only chilled to 50 F 10 C New installation Allow 24 hours after installation for the water suppl...

Page 17: ...ethylene 0 005 mg L 0 015 mg L 0 015 mg L 10 0 0005 mg L 0 0005 mg L 96 6 96 6 Test Parameters pH 7 5 0 5 unless otherwise noted Flow 0 78 gpm 2 9 Lpm Pressure 60 psig 413 7 kPa Temp 68 F 5 F 20 C 3 C...

Page 18: ...0 0 0048 mg L 0 11 mg L 99 80 99 90 Chlorobenzene 0 1 mg L 2 0 mg L 2 0 mg L 10 0 0038 mg L 0 0008 mg L 99 80 99 90 Endrin 0 002 mg L 0 007 mg L 0 006 mg L 10 0 0004 mg L 0 0002 mg L 94 30 96 80 Test...

Page 19: ...tion on how to use your product 3 Service to correct improper product maintenance or installation installation not in accordance with electrical or plumbing codes or correction of household electrical...

Page 20: ...RANT A Maytag no hace declaraciones acerca de la calidad durabilidad o necesidad de servicio t cnico o reparaci n de este electrodom stico principal aparte de las declaraciones incluidas en esta garan...

Reviews: