Page 1: ...HOSES 14 CONNECT VENT 16 LEVEL DRYER 16 COMPLETE iNSTALLATiON CHECKLIST 17 REVERSE DOOR SWING 17 TROUBLESHOOTING 19 iNSTALLATiON NOTES Date of purchase Date of installation installer Model number Ser...
Page 2: ...the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING Risk of Fire Clothes dryer installation must be performed...
Page 3: ...ips new vent installations 5 inlet hose Rubber washer Parts package is located in dryer drum Check that all parts are included Parts needed Not supplied with dryer Check local codes Check existing ele...
Page 4: ...door is installed top and bottom air openings in door are required IMPORTANT Do not operate install or store dryer where it will be exposed to water weather or at temperatures below 45 F 7 C Lower tem...
Page 5: ...do not permit the connection of a neutral ground wire to the neutral wire see Optional 3 wire connection section A 4 wire power supply connection must be used when the appliance is installed in a loca...
Page 6: ...w UL listed 30 amp power supply cord Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire...
Page 7: ...r outlet looks like this Power supply cord 4 wire receptacle NEMA Type 14 30R Go to 4 Wire Power Supply Cord Connection on this page Power supply cord 3 wire receptacle NEMA Type 10 30R Go to 3 Wire P...
Page 8: ...10 30R 3 prong plug Spade terminals with upturned ends Ring terminals Connect ground wire F green or bare of power supply cord to external ground conductor screw A Tighten screw Remove center termina...
Page 9: ...dryer cabinet and be in a horizontal position Tighten strain relief screw against the direct wire cable if your wiring looks like this 4 wire direct connection Go to 4 Wire Direct Connection on this...
Page 10: ...hten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 3 WIRE DIRECT WiRE CONNECTION Use where local co...
Page 11: ...of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements OPTIONAL 3 WIRE CONNECTION You must verify with a qualified electrician that thi...
Page 12: ...uced airflow and poor performance Do not install in enclosed walls ceilings or floors The total length should not exceed 7 3 4ft 2 4 m NOTE If using an existing vent system clean lint from entire leng...
Page 13: ...es Venting systems come in many varieties Select the type best for your installation Two close clearance installations are shown Refer to the manufacturer s instructions j A B A Over the top installat...
Page 14: ...54 ft 16 5 m 44 ft 13 4 m 35 ft 10 7 m 27 ft 8 2 m Angled hoods 58 ft 17 7 m 48 ft 14 6 m 38 ft 11 6 m 29 ft 8 8 m 21 ft 6 4 m NOTE Bottom exhaust installations have a 90 turn inside the dryer To dete...
Page 15: ...or and tighten couplings One end of the long hose has a wire mesh strainer inside the coupling Attach this end to the Y connector Attach washer cold inlet hose to other side of Y connector Screw on co...
Page 16: ...inal location Avoid crushing or kinking vent After dryer is in place remove cardboard from under dryer LEVEL DR_R 1 Level Dryer Place level _ Place level Check levelness of dryer from side to side Rep...
Page 17: ...ion Start button has been pushed firmly Dryer is plugged into an outlet and or electrical supply Household fuse is intact and tight or circuit breaker has not tripped Dryer door is closed This dryer a...
Page 18: ...o hinges from the dryer door I 2 Replace the 4 screws in the same holes 3 Remove the 4 screws from the opposite side of the door 4 Install the two hinges to the front panel of the dryer using 4 screws...
Page 19: ...rician AF low airflow condition The dryer will continue to run when this diagnostic code is present Press any key to clear the code from the display and return to the estimated time remaining Select a...
Page 20: ...can result in death explosion or fire Is the dryer located in a closet Closet doors must have ventilation openings at the top and bottom of the door The front of the dryer requires a minimum of 1 25 m...