Maytag AKS3040 Technical Information Download Page 1

Technical Information

Gas Cooktop

March 2003

16022195 Rev. 0

1

AKS3040*

CGC2430AD*

JGC6430AD*

MGC5430BD*

MGC6430BD*

• 

Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.

• 

Refer to Service Manual 16022158 for detailed installation, operating, testing, troubleshooting, and disassembly
instructions.

CAUTION

!

All safety information must be followed as provided in Service Manual 16022158.

!

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.

Model

AKS3040*

CGC2430AD*

JGC6430AD*

MGC5430BD*

MGC6430BD*

Power Source

Voltage rating

120 VAC

120 VAC

120 VAC

120 VAC

120 VAC

Amperage rating

10 Amp

10 Amp

10 Amp

10 Amp

10 Amp

Frequency

60 Hz

60 Hz

60 Hz

60 Hz

60 Hz

Water Column Pressure

Natural

4 in. W.C.P.

4 in. W.C.P.

4 in. W.C.P.

4 in. W.C.P.

5 in. W.C.P.

LP/Propane

10 in. W.C.P.

10 in. W.C.P.

10 in. W.C.P.

10 in. W.C.P.

10 in. W.C.P.

Surface Burner (BTU Nat. / LP)

Type of burner

Sealed

Sealed

Sealed

Sealed

Sealed

Right front

12.5 K/10.5 K

12.5 K/10.5 K

12.5 K/10.5 K

12.5 K/10.5 K

12.5 K/10.5 K

Right rear

9.2 K / 9.1 K

9.2 K / 9.1 K

9.2 K / 9.1 K

9.2 K / 9.1 K

9.2 K / 9.1 K

Left front

9.2 K / 9.1 K

9.2 K / 9.1 K

9.2 K / 9.1 K

9.2 K / 9.1 K

9.2 K / 9.1 K

Left rear

5 K / 4 K

9.2 K / 9.1 K

5 K / 4 K

5 K / 4 K

5 K / 4 K

Features

Grate sytle

One-piece

continuous

Square

One-piece

continuous

One-piece

continuous

One-piece

continuous

Grates material

Cast

Heavy steel

Heavy cast

Cast

Cast

Cooktop surface

Porc/steel

Porc/steel

Temp glass

Porc/steel

Porc/steel

Electronic ignition

X

X

X

X

X

Product cutout dimensions
in. (cm)

Width

28.5 (72.4)

28.5 (72.4)

28.5 (72.4)

28.5 (72.4)

28.5 (72.4)

Depth

19.9 (50.6)

19.9 (50.6)

19.9 (50.6)

19.9 (50.6)

19.9 (50.6)

Nat / LP Orifice Spuds

12.5 K / 10.5 K

1.85 / 0.97

1.85 / 0.97

1.85 / 0.97

1.85 / 0.97

1.85 / 0.97

9.2 K / 9.1 K

1.55 / 0.91

1.55 / 0.91

1.55 / 0.91

1.55 / 0.91

1.55 / 0.91

5 K / 4 K

1.10 / 0.64

1.55 / 0.91

1.10 / 0.64

1.10 / 0.64

1.10 / 0.64

Summary of Contents for AKS3040

Page 1: ...C P 4 in W C P 5 in W C P LP Propane 10 in W C P 10 in W C P 10 in W C P 10 in W C P 10 in W C P Surface Burner BTU Nat LP Type of burner Sealed Sealed Sealed Sealed Sealed Right front 12 5 K 10 5 K 12 5 K 10 5 K 12 5 K 10 5 K 12 5 K 10 5 K 12 5 K 10 5 K Right rear 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K Left front 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K Lef...

Page 2: ...Test for resistance of spark lead Test ignitor to chassis Continuity No continuity from ignitor to chassis Spark ignition electrode Test for resistance of spark lead Test ignitor to chassis Continuity No continuity from ignitor to chassis Top surface burner Verify gas is supplied Verify burner cap is positioned correctly Check for obstructions in burner ports L A B A1 B1 N Spark module 4 0 Test fo...

Page 3: ...ve pin from cap 3 Apply downward finger pressure at the disc edges to place pin into the cap LP L P Natural NAT 4 Place pressure regulator cap on pressure regulator and tighten Low Flame Adjustment Properly adjusted burner flames are clean and blue with a distinct inner cone approximately inch long 1 Remove control knob from valve stem 2 Carefully remove rubber grommet from cooktop 3 Locate valve ...

Page 4: ... power to oven before servicing unless testing requires power 16022195 Rev 0 March 2003 4 TOP BURNER IGNITION SWITCHES TOP IGNITORS SPARK MODULE N L BLK BLK BLK BLK TAN TAN TAN TAN TOP IGNITORS SPARK MODULE N L NEUTRAL LINE GROUND POWER CORD TOP BURNER IGNITION SWITCHES SCHEMATIC WIRING DIAGRAM 8104P828 60 ...

Reviews: