4
CHECK YOUR VENT SYSTEM FOR GOOD AIR FLOW
Good air flow
Along with heat, dryers require good air flow to efficiently dry
laundry. Proper venting will reduce your drying times and
improve your energy savings. See Installation Instructions.
The venting system attached to the dryer plays a big role
in good air flow.
Service calls caused by improper venting are not covered by
the warranty and will be paid by the customer, regardless of
who installed the dryer.
To maintain good air flow:
Good
Better
USE AUTOMATIC DRY CYCLES FOR BETTER FABRIC CARE AND ENERGY SAVINGS
Use the Automatic Dry cycles to provide the most energy savings and enhanced fabric care from the dryer. During Automatic Dry cycles,
drying air temperature or moisture level are sensed in the load. This sensing occurs throughout the drying cycle and the dryer shuts off
when the load reaches the selected dryness.
With Timed Dry, the dryer runs the amount of time set and sometimes results in shrinkage, wrinkling, and static due to over-drying. Use
Timed Dry for the occasional damp load that needs a little more drying time or when using the drying rack.
■
Clean your lint screen before each load.
■
Replace plastic or foil vent material with 102 mm (4")
diameter heavy, rigid vent material.
■
4"
102 mm
Use the shortest length of vent possible.
■
Use no more than four 90° elbows in a vent system;
each bend and curve reduces air flow.
■
Remove lint and debris from the exhaust hood.
■
Remove lint from the entire length of the vent system
at least every 2 years. When cleaning is complete, be
sure to follow the Installation Instructions supplied with
your dryer for final product check.
■
Clear away items from the front of the dryer.
SPECIFICATIONS
These units are sold in multiple regions with different requirements
for measuring capacity. Below are a few of the valid forms of
measure posted on this product:
Dry Linen Capacity:
A weight measure in load size that reflects the
volumetric size of the dryer drum.
Rated Capacity:
This represents the maximum capacity of dry
linens and textiles which the manufacturer declares can be treated in
a specific cycle.
Models
4KMEDC410JW
4KMEDC420JW
4KMEDC430JW
4KMEDC440JW
Rated Voltage
220–240 V 2N~
Rated Frequency
60 Hz
Rated Current
20 A
Dry Linen Capacity
(Maximum)
15 kg (33 lb)
Rated Capacity
7 kg (15 lb)
Height
1067 mm (42")
Width
737 mm (29")
Depth
706 mm (27
13
⁄
16
")
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in
death or fire.
Summary of Contents for 4KMEDC410JW