4-12
1. To access the soap signal board on an OPL
washer, remove four T-20 screws securing
the cover to the back panel.
2. Pull the bottom edge of the cover away
from the back panel and slide it to the right
to release the tab at the top of the cover
from the slot in the back panel.
3. When looking at the board, the power
connection is at the lower right side, ACU
signal connection is at the upper right side,
and connections for liquid chemical pumps
is at the upper left side.
4. The strain relief at the lower left corner of
the board is for the soap signal wires.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.
SOap SiGnaL BOarD
Four T-20
Screws