4-7
1. The EMI filter filters out electromagnetic line
noise from the incoming power source.
2. To remove the EMI filter, use a Phillips head
screwdriver to loosen retainers for the wires.
3. Pull the wires out of the retainers.
4. Use a 10mm wrench to remove the nut
securing the ground wire.
5. Remove the lock washer, flat washer, and
ground wire.
6. There is another flat washer behind the
ground wire.
7. Remove two 7mm hex nuts from each side
of the EMI filter, securing the filter to the
component tray.
8. It may be easier to use a magnet to retrieve
the nuts and washers.
9. Lift the EMI filter up off the bolts and
remove it.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.
eMi FiLTer
Four Phillips
Screws
10mm
Ground Nut
Four 7mm
Hex Nuts