background image

 

 

Stand 40-0414 

English 

page 1 of 13 

Installation instruction AZ256, AZ257, AZ258 and AZ259 

 

Customized base plate, free-standing, with placement hinge and upper anchor tube AZ120 for 
ALBATROS Parasols. Please refer to the MAY brochure „commercial parasols“ for the weights 

required per model. Go to “ALBATROS – Sizes and Technical Data” and look up the “Minimum-

ballast”. In case of non-compliance, the MAY company cannot assume any liability.  
 

The following instructions include all information necessary for the assembly of this base pedestal. 
To avoid any misunderstanding, we advise you to read these instructions carefully and then keep 

them for later reference. 

 

Non- observation of mounting instructions can result in personal 

injuries or damage to property.  
Please note that if these instructions are not observed, the manufacturer cannot 

assume any liability or guarantee. 

 

Always follow the safety regulations. 

 

Should you not understand any part of these mounting instructions, please 

contact your MAY dealer. 

 

 

Diagram showing mounting procedure 

 

 

 

 

Caution 

bore hole for theft and 

anti-twisting lock 

 

placement hinge 

 

base plate, 4x 

 

n

o

vi

sible

 a

ft

er

 

in

st

al

la

ti

o

n

 

 

 

 

u

p

p

er

 t

u

b

 

 

vi

sible 

af

ter

 i

n

st

al

la

ti

o

n

 

 

 

 

b

o

tt

o

m

 co

mp

o

n

en

t/

 

b

ase

 

 

 

 

flange plate

 

 

Summary of Contents for PARASOLS AZ256

Page 1: ...f this base pedestal To avoid any misunderstanding we advise you to read these instructions carefully and then keep them for later reference Non observation of mounting instructions can result in pers...

Page 2: ...Stand 40 0414 English page 2 of 13 wooden planking reinforced concrete base...

Page 3: ...onent is not set too far down in the ground If there is a difference of more than 50 mm between the top of the lower anchor tube and the floor surface the placement hinge cannot be tilted and the para...

Page 4: ...n of the main axis of the parasol Allow enough clearance between parasols or from walls Parasols that are located too close together wear sooner Parasols may sway slightly If there is not enough space...

Page 5: ...5 of 13 4 For AZ257 AZ258 and AZ259 now add the additional steel plates Use the enclosed hexagonal screws M5 x 60 mm as spacers and for assembly between the individual steel plates to ensure prescise...

Page 6: ...and AZ259 now use the 4 hex socket head screws to connect the additional layers of steel plates with each other one at each corner 2 layers of steel plates M16 x 30 mm 3 layers of steel plates M16 x 4...

Page 7: ...ightened firmly enough there will not be sufficient tensile force to trigger self locking If the screws are tightened too firmly and over stressed the screw connection may slacken Tighten the M16 cyli...

Page 8: ...so put the M16x30mm countersunk screw and tighten it using the 10 mm hex key and extension provided 8 Slip the 12 mm washer on the M12x30mm countersunk screw and tighten it using the 8 mm hex key pro...

Page 9: ...below the terrace surface cf illustration The difference of 4 mm corresponds to the thickness of the checker plate Be sure to order bottom component with the correct height measurements so that it wi...

Page 10: ...f the upper anchor tube of AZ256 AZ257 AZ258 AZ259 is not in an absolutely vertical position the parasol will stand slanted This would have a negative impact on the overall optical appearance in parti...

Page 11: ...wire by a qualified electrician Electric installation work should be carried out solely by a certified electrician Disregarding this warning may result in serious personal injuries Personal injury in...

Page 12: ...ground cable from the cable in the parasol pole Lift the parasol out of the anchor foot 2 Remove the upper anchor tube completely by screwing it off 3 Screw the top plate onto the lower anchor tube cf...

Page 13: ...nvolved should discuss this installation option on site If these instructions are provided to everyone during the planning period arguments can be harmonised and therefore unnecessary costs for incorr...

Page 14: ...Z256 Art no AZ256 Multi piece screw off upper part and base spacer for centre pole 100 mm mounted on site heaviest part approx 63 kg base plate size 147x147 cm steel plate thickness x 15 mm hot dip ga...

Page 15: ...______mm min 100 mm max 600 mm winter top plate Cable gland for tension relief Only necessary if power supply is planned required ______ not required ______ mandatory When ordering please fill in the...

Page 16: ...Z257 Art no AZ257 Multi piece screw off upper part and base spacer for centre pole 100 mm mounted on site heaviest part approx 63 kg base plate size 147x147 cm steel plate thickness x 15mm hot dip gal...

Page 17: ...r supply is planned required ______ not required ______ mandatory When ordering please fill in the fields below Quantity mandatory Dealer Name and address optional Dealer Commission optional Dealer Or...

Page 18: ...Z258 Art no AZ258 Multi piece screw off upper part and base spacer for centre pole 100 mm mounted on site heaviest part approx 63 kg base plate size 147x147 cm steel plate thickness x 15mm hot dip gal...

Page 19: ...r supply is planned required ______ not required ______ mandatory When ordering please fill in the fields below Quantity mandatory Dealer Name and address optional Dealer Commission optional Dealer Or...

Page 20: ...259 This order sheet must be filled out completely and supplied to the MAY company before production Art no AZ259 Multi piece screw off upper part and base spacer for centre pole 100 mm mounted on sit...

Page 21: ...supply is planned required ______ not required ______ mandatory When ordering please fill in the fields below Quantity mandatory Dealer Name and address optional Dealer Commission optional Dealer Ord...

Reviews: