Residential  Grade  Passive Infrared  Occupancy   S ensor    W a l l   S witch-AUTO 

ON/AUTO  OFF

 

 

 

Ratings

 

Incandescent   / Tungsten:    500W-120VAC,  
50/60Hz; Resistive  load:  500W-120VAC,  
50/60Hz; Fluorescent  / Ballast:  500VA-
120VAC,  50/60Hz Motor:   1/8HP-120V

 

INDOOR   USE   ONLY

 

No  Minimun Load  required.

 

Compatible  with  incandescent  lamps,  electronic  and  mag- 

netic  low-voltage  ballasts,  electronic  and  magnetic  
ballasts, and  fans

 

 

   INSTALLATION INSTRUCTIONS  

 

 

Description:

 

Model  MEW-OS500  senses  occupancy  by  detecting  the 

difference  between  heat  emitted  from  the  human  body  in  motion 
and  the  background  space.  This  device  operates  by  detecting 
motion  within  its  field-of-view  (Figure  1)  and  automatically 
switches lights ON. When motion is no longer detected, lights re- 
main ON for a selected time and automatically switch OFF. It is suit- 
able for indoor use only. It is ideal for any room in your home that 
would  benefit  from  automatic  light  control,  such  as  bathrooms, 
bedrooms, and living areas.

 

 

.

 

 

SPECIFICATIONS:

 

 

Built-in photocell, increases energy savings.

 

Adjustable detection ranges of light level, distance and time delay 

are located on the front of the device (Figure 2).

 

When the switch is in automatic(AUTO) mode, the LED indicator 

flashes when the motion is detected.

 

Installing this device requires experience with residential and com- 

mercial wiring practices. Consult local building codes before attempt- 
ing to install this device.

 

Operating Temperature: 68˚F-77˚F

 

 

Figure 1: Coverage Pattern:

 

   GENERAL INFORMATION  

 

 

Clean outer surface gently with damp cloth only. Do not use soaps or 

cleaning liquids.

 

Do not attempt to service or repair. No user serviceable components.

 

 

 

LOCATION/MOUNTING

 

 

Since this device responds to temperature changes, care should 

be taken when mounting the device. DO NOT mount directly above a 
heat source, in a location where hot or cold drafts will blow directly on 
the sensor, or where unintended motion will be within sensor’s field-of- 
view.

 

Precautions

 

WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE 

WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.

 

WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF 

THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.

 

CAUTION: USE THIS DEVICE ONLY WITH COPPER OR COP- 

PER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES 
MARKED CO/ALR OR CU/AL.

 

 

 

INSTALLATION

 

 

1. WARNING: TO AVOID FIRE, SHOCK,  OR DEATH, TURN  OFF 
POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE 
POWER IS OFF BEFORE WIRING!

 

2.  Remove  existing  single-pole  switch  or  dimmer  installation,  if

 

applicable.

 

3. Remove 3/4’’ (1.9 cm) of insulation from each wire. Make  sure  the 
ends of wires are straight.

 

4. Connect device lead wires per WIRING DIAGRAM as follows: Black 
lead to Line (Hot), Red lead to Load wire, White lead to Neutral wire, 
Green  lead  to  Ground.  Twist  strands  of  each  wire  tightly.    Push 
firmly  into  appropriate  wire  connector.  Screw  connectors  on 
clockwise  ensuring  that  no  bare  conductor  shows  below  the  wire 
connectors. Secure each connector with electrical tape.

 

 

NOTE:

 

If wire nut is provided, use to join one 14 AWG supply conductor 

with one 16 AWG device control lead.

 

5. Gently position wires to provide room in wall box for sensor 

switch.

 

6. Mount device “TOP” up.

 

7. Restore power at circuit breaker or fuse.

 

8. Locate the adjustment controls on the front of the switch. Proceed to

 

the “SETTINGS” section.

 

 

Wiring Diagram:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure:2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control panel:

 

 

 

 

 

TIME  

RANGE  

LIGHT

 

 

 

PROGRAMMING FEATURES

 

 

Factory settings: 

The sensor is shipped from the factory to work in 

almost all situations without any added adjustments. The factory set- 
tings are: time-out 10 minutes;  lights always turn ON regardless of 
existing light levels;  intermediate detection range.

 

.

 

 

-01-

 

 

-02-

 

 

-03-

 