Maxx Cold MCF-23FD Installation And Operation Manual Download Page 1

Installation and Operation Guide

For

MCF-49FD, MCF-23FD

MCR-49FD, MCR-23FD

Summary of Contents for MCF-23FD

Page 1: ...Installation and Operation Guide For MCF 49FD MCF 23FD MCR 49FD MCR 23FD ...

Page 2: ...The serial number is located on the rating label which is on the left interior wall Please retain the unit s serial number for service purposes 2 2 3 4 4 5 6 7 8 9 10 11 Solid Door Refrigerators MODEL COMP H P REFRIGERANT AMPERAGE POUNDS MCR 23FD 1 3 R 134a 420W 271 MCR 49FD 1 2 R 134a 570W 370 Solid Door Freezers MODEL COMP H P REFRIGERANT AMPERAGE POUNDS MCF 23FD 1 3 R 134a 440W 284 MCF 49FD 1 2...

Page 3: ...e to avoid hot corner or location near stove oven or other heat source High ambient temperature will make cooling efficiency lower 4 INDOOR USAGE ONLY This equipment is intended for indoor use only 5 STABILIZING Make sure the unit is installed in a stable condition with the front wheels locked while in use 6 LEVELING Be sure that the unit is level from front to back and side to side 7 Unit should ...

Page 4: ...e warm water and a mild soap 4 CHECK AFTER CLEANING Check the unit again for safety Check that the unit is operating properly 1 POWER CORD Be sure the power cord is connected to the proper voltage Compressor warranties are void if compressor burns out due to improper voltage A protected circuit of the correct voltage and amperage must be run for connection of the line cord Turn off the power switc...

Page 5: ...l begin to run 2 The default temperature setting is 35ᵻ 1ᴱ 3 The compressor is automatically cycled by the electronic controller PCB 4 Temp Control range 39ᵻ 28ᵻ 7ᴱ 3ᴱ 5 The interior light is activated by the door switch when the door is opened 6 Evaporator fan motor s will run after all doors are completely closed MCR 23FD MCR 49FD REFRIGERATOR ...

Page 6: ...you can set the inside temperature 2 DOOR OPENING INDICATOR If door is opened door opening indicator will be turned on If the door is left open for 5 minutes an alarm will sound continuously The alarm will stop immediately upon closing the door INSIDE TEMP TEMP CONTROL BUTTON DOOR OPENING ...

Page 7: ...ᵻ 18ᴱ 3 The compressor is automatically cycled by the electronic controller PCB D sensor 4 The Defrost cycle is automatically controlled by the D sensor and the PCB 5 Temp Control range 5ᵻ 9ᵻ 3ᴱ 24ᴱ 6 The interior light is activated by the door switch at the bottom of the grill when the door is opened 7 Evaporator fan motor s will run after all doors are completely closed MCF 23FD MCF 49FD FREEZER...

Page 8: ...a defrost cycle every 6 hours Once all frost is eliminated the defrost control is changed to the freezer mode The panel displays during the defrost 3 DOOR OPENING INDICATOR If door is opened door opening indicator will be turned on If the door is left open for 5 minutes an alarm will sound continuously The alarm will stop immediately upon closing the door INSIDE TEMP TEMP CONTROL BUTTON DOOR OPENI...

Page 9: ...ing screws Upper or downward located ῡ in the PICTURE A 2 Remove GRILL by removing securing screws connected Left and right side located ῢ in the PICTURE A Caution Disconnect power before reversing door use caution with cares associated with electronic control ῡ ῢ TOP GRILL ῢ M5 27 SCREW Ῡ M5 27 SCREW ΰ DOOR HINGE UPPER ῡ DOOR HINGE STOP PIN ῥ DOOR HINGE BUSHING ῧ DOOR HINGE BUSHING ῦ DOOR ASSEMBL...

Page 10: ...SSEMBLY ῦ locate the HANDLE in the desired side 2 Assemble in the following order After assembling ΰῢL assemble ῤῥ Insert into ῤ DOOR ASSEMBLY of ῦ After inserting ῧῨ secure ΰῩ Insert reversible for suitable spring elasticity Attention Securely tighten all fastners Ῡ M5 27 SCREW ΰ DOOR HINGE LOWER Ῠ DOOR HINGE SHAFT LOWER ῦ DOOR ASSEMBLY ῥ DOOR HINGE BUSHING ῡ DOOR HINGE STOP PIN ΰ DOOR HINGE UPPE...

Page 11: ...exterior High moisture air can produce dew drops during high condensation humidity Wipe with a dry cloth There is condensation the unit interior The door is opened too frequently or left open too long Damp food is stored Keep the door closed to remove condensation The door does not close tightly The door is bent The door gasket has come out The unit is not level Reposition the gasket Level the uni...