MaxStream 9XCite XC09-009PKC-UA Product Manual Download Page 1

Distributor of Digi International: Excellent Integrated System Limited

Datasheet of XC09-009PKC-UA - MODEM RF 900MHZ USB 9600 W/ACC 
Contact us: [email protected] Website: www.integrated-circuit.com

 

 

Excellent Integrated System Limited

Excellent Integrated System Limited

Stocking Distributor

Stocking Distributor

Click to view price, real time Inventory, Delivery & Lifecycle Information:

Click to view price, real time Inventory, Delivery & Lifecycle Information:

Digi International

Digi International

XC09-009PKC-UA

XC09-009PKC-UA

 

 

 

 

For any questions, you can email us directly:

For any questions, you can email us directly:

[email protected]

[email protected]

                             1 / 36

                             1 / 36

Summary of Contents for 9XCite XC09-009PKC-UA

Page 1: ...ed Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery...

Page 2: ...tream 355 South 520 West Suite 180 Lindon UT 84042 Phone 801 765 9885 Fax 801 765 9895 rf xperts maxstream net www MaxStream net live chat support 9XCite PKG U USB RF Modem 9XCite USB RF Modem RF Mode...

Page 3: ...PKG U USB RF Modem Product Manual v2 1 2007 01 04 2007 MaxStream Inc ii 2007 MaxStream Inc All rights reserved No part of the contents of this manual may be transmitted or reproduced in any form or b...

Page 4: ...Mode 10 2 3 3 Receive Mode 11 2 3 4 Sleep Modes 12 2 3 5 Command Mode 14 3 RF Modem Configuration 15 3 1 Command and Parameter Types 15 3 1 1 AT Commands 15 3 1 2 Non AT Settable Parameters X CTU Sof...

Page 5: ...08 dBm 9600 baud 104 dBm 38400 baud Advanced Networking Security True Peer to Peer no master required Point to Point Point to Multipoint networking Hopping Frequency Hopping Spread Spectrum or Single...

Page 6: ...equirements Supply Voltage 5 12 VDC external or USB bus power Transmit Current 105 mA Receive Current 55 mA Power down Current 1 mA Networking Security Frequency 902 928 MHz Spread Spectrum Frequency...

Page 7: ...it 1 02d Power Connector 5 12 VDC Power Connector Power can also be supplied through the VBUS pin of the USB port 1 03a Reset Switch Figure 1 03 Back View Pressing the Reset Switch forces the modem in...

Page 8: ...supply The external power must supply a DC voltage between 5 and 12 V The power supply currently shipped with MaxStream Development Kits is a suitable power supply for this option XCite PKG U RF Modem...

Page 9: ...ubsequent uses A USB client should not be plugged into another client If another USB client such as a USB video camera is plugged into a MaxStream USB RF modem also a client the devices will not commu...

Page 10: ...used to describe a data system that includes the XCite USB RF Modem XCite PKG U USB RF Modem PKG U The Ethernet RF Modem is an USB connected serial modem used for communication with other MaxStream se...

Page 11: ...he DI Buffer Receive Mode Valid RF data is received through the antenna Sleep Mode Sleep Mode condition is met Command Mode Command Mode Sequence is issued 2 3 2 Transmit Mode When the first byte of s...

Page 12: ...it goes through the receiving end of a CRC cyclic redundancy check to ensure that the data was transmitted without error If the CRC data bits on the incoming packet are invalid the packet is discarde...

Page 13: ...il the Sleep pin is de asserted The XCite Module requires 40ms to transition from Sleep Mode to Idle Mode Pin 2 is only active if the modem is setup to operate in this mode otherwise the pin is ignore...

Page 14: ...can begin transmitting or receiving data It remains active until no data is detected for the period of time specified by the ST parameter at which point it resumes its low power cyclic state Note The...

Page 15: ...ddress to 0x1F To store the new value to non volatile long term memory the Write ATWR command must subsequently be sent before powering off the modem System Response When a command is sent to the mode...

Page 16: ...within the set are organized under the following categories AT Commands Non AT Settable Parameters 3 1 Command and Parameter Types 3 1 1 AT Commands AT Commands can be changed at any time by entering...

Page 17: ...ouble click the setup_X CTU exe file and follow prompts of the installation screens This file is located in the software folder of the MaxStream CD and also under the Downloads section of the followin...

Page 18: ...the last received packet 0x25 0x6A Read only Diagnostic 1 DT Destination Address Set the address that identifies the destination of the RF packet Only radio modems having matching addresses can commun...

Page 19: ...matically exits from AT Command Mode 0x02 0xFFFF x 100 ms AT Command Mode Options 2 0xC8 200d FL Software Flow Control Enable serial software flow control on the radio modem Hardware flow control CTS...

Page 20: ...ed AT Parameter is used to adjust the period of silence that follows the command sequence character Parameter Range 0x02 0xFFFF x 1 millisecond of bytes returned 2 Default Parameter Value 0x1F4 500 de...

Page 21: ...ameter Range 0 0xFFFF x 1 millisecond of bytes returned 2 Default Parameter Value 0x1F4 500 decimal Related Commands AT Guard Time After CC Commands Sequence Character CC Command Sequence Character Pa...

Page 22: ...econds DB Receive Signal Strength Command AT Command Diagnostic DB Parameter returns the receive signal strength in decibels of the last received packet This Parameter is useful in determining range c...

Page 23: ...Radio Modem can operate both in Hop ping and Single Frequency Channel Modes Switching between Single Channel and Hopping Modes can only be done only using the Function Set dropdown list on the Modem...

Page 24: ...time elapses and the ST Time before Sleep Parameter is met the receiver goes into cyclic sleep Once in cyclic sleep the radio modem must first detect the wake up initializer and synchronize to the tr...

Page 25: ...the wake up initial izer to a specific amount of time in x 100 ms The long wake up initializer must be longer than the cyclic sleep time that is determined by SM Sleep Mode Command If the wake up ini...

Page 26: ...ther an odd number of 1 s or an even number of 1 s For example if parity is odd then any group of bits that arrives with an even number of 1 s must contain an error PW Pin Wake up Parameter Non AT Set...

Page 27: ...transmission SH Serial Number High Command AT Command Diagnostic SH Command reads and returns the RF modem serial number high word AT Command SH Parameter Range 0 0xFFFF Read only of bytes returned 2...

Page 28: ...er ST Parameter sets the period of time in tenths of seconds in which the radio modem remains inactive before entering into Sleep Mode For example if the ST Parameter is set to 0x64 100 decimal the ra...

Page 29: ...el and Desti nation Address layers The Destination Address is the last network layer and provides the most granular form of filtration If at any point during the incoming RF data flow the numbers in q...

Page 30: ...n a network can be configured with a 16 bit Destination Address to establish selective communications within a network This address is set to one of 65535 values using DT Destination Address Command T...

Page 31: ...using MK Address Mask Command The default value of the MK Parameter is 0xFFFF All transmitted data packets contain the Destination Address of the transmitting modem When a transmitted packet is receiv...

Page 32: ...ications If the modem will be used for portable applications the device must undergo SAR testing This equipment has been tested and found to comply with the limits for a Class B digital device pursuan...

Page 33: ...no manual instructions to remove adjust or install the device FCC approved Antennas WARNING This device has been tested with Reverse Polarity SMA connectors with the antennas listed in the tables of...

Page 34: ...m 801 765 9885 for more information IC Industry Canada Certification Labeling Requirements Labeling requirements for Industry Canada are similar to those of the FCC A clearly visible label on the outs...

Page 35: ...RICE OF THE PRODUCT FOR ANY LOSS OF USE LOSS OF TIME INCONVENIENCE COMMERCIAL LOSS LOST PROFITS OR SAVINGS OR OTHER INCIDENTAL SPECIAL OR CONSE QUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO...

Page 36: ...Free and unlimited technical support is included with every MaxStream Radio Modem sold For the best in wireless data solutions and support please use the following resources MaxStream office hours are...