1.5 Servo motor installation
9
>50mm
>50mm
>
1
0
0
m
m
>
1
0
0
m
m
>100mm
通风气流方向
X3
X1
X2
X3
X1
X2
X3
X1
X2
1.5
Servo motor installation
1.5.1
The environmental conditions for installation
Ambient temperature: 0 to 40
℃
; Ambient humidity: less than 80 %( no dew).
Storage temperature: -40 to 50
℃
; Storage humidity: less than 93 %( no dew).
Vibration: less than 0.5G.
Install the servomotor in well-ventilated place with less moisture and a few dusts.
Install the servomotor in a place without corrosive liquid, flammable gas, oil vapor, cutting
cooling liquid, cutting chips, iron powder and so on.
Install the servomotor in a place without water vapor and direct sunlight.
1.5.2
The method of installation
For horizontal installation: In order to prevent water, oil, etc. from entering inside of the
servomotor, please put the cable connector downward.
For vertical installation: if the shaft of the servo motor is in upward direction with a speed
reducer, some prevention measure shall be taken against entering inside of the servomotor by
oil come from the speed reducer.
Motor shaft extension should be long enough, or may cause vibration while motor is in
running
In case of installation or removing the servomotor, please do not hit the servomotor with a
hammer, otherwise the shaft and the encoder can be damaged.
Summary of Contents for EP3E Series
Page 10: ......