Extended Door/Window Sensor
RF-CMDWSX-345-NN
Installation Manual
RF-CMDWSX-345-NN IM V1 03152021
Description
The Extended Door/Window Sensor is a
supervised, wireless sensor that detects
the opening and closing of doors or windows.
The sensor and magnet are mounted using
screws (included) or
double-sided adhesive tape (included).
When activated, the sensor transmits an
open (trip) or close (restore) signal to the
panel. These are the signals the unit
provides: supervisory, tamper, and low battery (as
needed). The sensor is powered by (2) replaceable 3-
VDC, lithium coin-cell batteries.
Cover
Programming
The following steps describe the general guidelines for
programming the sensor into panel memory. Refer to the
specific panel’s documentation for complete programming
details.
1. Set the panel to the program mode.
2. Proceed to the SENSORS menu.
3. Select the appropriate sensor group and sensor number
assignments.
4. When prompted by the panel, trip the sensor for learning
by remove the sensor cover and if present pull the battery
pull tabs or enter the sensor ID#. The system should
acknowledge the sensor by touchpad display and/or audio
(depending on the panel).
5. Honeywell Loop Assignment:
-External terminal - Loop 1
-Internal reed switch - Loop 2
6. Exit program mode.
Tamper
Batteries
Terminals
External Contact
Base
Tamper Base
Note: Do not exceed 50 ft.
when wiring to an external
contact
Testing the Sensor
1. Set the panel to the sensor test mode.
2. Take the sensor and magnet to the desired mounting
location, making sure to line up their alignment marks with
each other. Trip the sensor by pulling the magnet away
from the sensor.
3. Monitor the system after tripping the sensor. Refer to the
specific panel documentation for interpretation of the
results to ensure desired signal strength is achieved.
Note:
If a low battery alarm occurs,
replace the battery within 7 days.
CAUTION
: Battery may explode if mistreated. Do not
recharge, disassemble or dispose of in fire.
Mounting the Sensor
Mount the sensor using the supplied mounting screws for
permanent mounting installations or using the supplied
double-sided tape is optional.
Note:
The gap between the sensor and magnet
Note: Only one set of contacts can be used at one time the
internal or external, for added security the internal reed
switch can be cut.
Installation Guidelines
1. Remove the transmitter’s cover by pressing in on the
small rectangular latch on the end of the cover and lift.
2. Mount the sensor base directly to the surface using the
mounting tape provided. Make sure to align the
mounting tape with the tamper pull put area on the
bottom of the sensor to insure proper tamper operation.
3. Mount the magnet next to the sensor and align the
magnet with the mark on the side of the sensor, using
the mounting tape provided, or connect an external
contact to the terminals.
4. Remove the battery isolator tabs from both batteries.
5. Replace the cover on the transmitter.
6. Enroll the senor into the control panel according
to the instructions.
should not exceed a maximum of 5/8”.
For Additional Tamper Security
Punch out the tamper cover on the bottom of the sensor,
and using the small screw secure it to the mounting
location, when the sensor is removed “tampered” the tab
remains providing a tamper condition.