Extended Door/Window Sensor 

RF-CMDWSX-345-NN

 

Installation Manual

 

RF-CMDWSX-345-NN IM V1 03152021

 

 

 

 

Description 

The Extended Door/Window Sensor is a 

supervised, wireless sensor that detects 

the opening and closing of doors or windows. 

The sensor and magnet are mounted using 

screws (included) or 

double-sided adhesive tape (included). 

 

When activated, the sensor transmits an 

open (trip) or close (restore) signal to the 

panel. These are the signals the unit 

provides: supervisory, tamper, and low battery (as 

needed). The sensor is powered by (2) replaceable  3- 

VDC, lithium coin-cell batteries. 

 

 

 

Cover 

Programming 

The following steps describe the general guidelines for 

programming the sensor into panel memory. Refer to the 

specific panel’s documentation for complete programming 

details. 

1. Set the panel to the program mode. 

2. Proceed to the SENSORS menu. 

3. Select  the  appropriate sensor  group  and sensor  number 

assignments. 

4. When prompted by the panel, trip the sensor for learning 

by remove the sensor cover and if present pull the battery 

pull tabs or enter the sensor ID#. The system should 

acknowledge the sensor by touchpad display and/or audio 

(depending on the panel). 

5. Honeywell Loop Assignment: 

-External terminal - Loop 1 

-Internal reed switch - Loop 2 

6. Exit program mode. 

 

 

Tamper 

Batteries 

Terminals 

 

External Contact 

 

 

Base 

 

 

 

Tamper Base 

 

 

 

 

 

 

 

 

Note: Do not exceed 50 ft. 

when wiring to an external 

contact 

Testing the Sensor 

1. Set the panel to the sensor test mode. 

2. Take the sensor and magnet to the desired mounting 

location, making sure to line up their alignment marks with 

each other. Trip the sensor by pulling the magnet away 

from the sensor. 

3. Monitor the system after tripping the sensor. Refer to the 

specific panel documentation for interpretation of the 

results to ensure desired signal strength is achieved. 

Note: 

If a low battery alarm occurs, 

replace the battery within 7 days. 

CAUTION

: Battery may explode if mistreated. Do not 

recharge, disassemble or dispose of in fire. 

 

Mounting the Sensor 

Mount the sensor using the supplied mounting screws for 

permanent mounting installations or using the supplied 

double-sided tape is optional. 

Note: 

The gap between the sensor and magnet 

Note: Only one set of contacts can be used at one time the 

internal or external, for added security the internal reed 

switch can be cut. 

 

Installation Guidelines 

1.  Remove the transmitter’s cover by pressing in on the 

small rectangular latch on the end of the cover and lift. 

2.  Mount the sensor base directly to the surface using the 

mounting tape provided. Make sure to align the 

mounting tape with the tamper pull put area on the 

bottom  of  the  sensor  to insure  proper  tamper operation. 

3.  Mount the magnet next to the sensor and align the 

magnet with the mark on the side of the sensor, using 

the mounting tape provided, or connect an external 

contact to the terminals. 

4.  Remove the battery isolator tabs from both batteries. 

5.  Replace the cover on the transmitter. 

6.  Enroll the senor into the control panel according 

to the instructions. 

should not exceed a maximum of 5/8”. 

For Additional Tamper Security 

Punch out the tamper cover on the bottom of the sensor, 

and using the small screw secure it to the mounting 

location, when the sensor is removed “tampered” the tab 

remains providing a tamper condition. 