3-33
The communication object possesses the identifier (=0) and consists of two bytes. The Node-ID defines the
destination of the message. If zero, the protocol addresses all NMT Slaves.
Figure 3-23
CAN communication – NMT object
Table 3-12
CAN communication – NMT protocols
Protocol
COB-ID
CS
(Byte 0)
Node-ID
(Byte 1)
Functionality
Enter
Pre-Operational
0
0x80
0 (all)
All CANopen nodes (EPOS4 devices) will enter NMT State “Pre-
Operational”.
0
0x80
n
The CANopen node (EPOS4 device) with Node-ID “n” will enter
NMT State “Pre-Operational”.
Reset
Communication
0
0x82
0 (all)
All CANopen nodes (EPOS4 devices) will reset the communication.
0
0x82
n
The CANopen node (EPOS4 device) with Node-ID “n” will reset the
communication.
Reset Node
0
0x81
0 (all)
All CANopen nodes (EPOS4 devices) will reset.
0
0x81
n
The CANopen node (EPOS4 device) with Node-ID “n” will reset.
Start Remote
Node
0
0x01
0 (all)
All CANopen nodes (EPOS4 devices) will enter NMT State
“Operational”.
0
0x01
n
The CANopen node (EPOS4 device) with Node-ID “n” will enter
NMT State “Operational”.
Stop Remote
Node
0
0x02
0 (all)
All CANopen nodes (EPOS4 devices) will enter NMT State
“Stopped”.
0
0x02
n
The CANopen node (EPOS4 device) with Node-ID “n” will enter
NMT State “Stopped”.