Setup
Connections
EPOS4 50/5 Hardware Reference
CCMC | 2022-04 | rel10445
3-25
3.3.5
Encoder (X5)
Best practice
• Differential signals offer good resistance against electrical interference. Therefore,
we recommend
using a differential scheme
. Nevertheless, the controller supports both schemes – differential and sin-
gle-ended (unsymmetrical).
• For best performance,
we strongly recommend using encoders with a line driver
. Otherwise, limita-
tions may apply due to slow switching edges.
• Even though 2-channel will do,
we strongly recommend to use only 3-channel versions
.
Figure 3-11
Encoder connector X5
Table 3-21
Encoder connector X5 – Pin assignment
Table 3-22
Encoder connector X5 – Accessories
Continued on next page.
X5
Head A
Prefab
Cable
Head B
Signal
Description
Pin
Color
Pin
1
brown
1
–
not connected
2
white
2
V
Sensor
Sensor supply voltage (+5 VDC; I
L
≤
100 mA)
3
red
3
GND
Ground
4
white
4
–
not connected
5
orange
5
Channel A\
Channel A complement
6
white
6
Channel A
Channel A
7
yellow
7
Channel B\
Channel B complement
8
white
8
Channel B
Channel B
9
green
9
Channel I\
Channel I complement
10
white
10
Channel I
Channel I
Accessories
Suitable strain
relief
Retainer
For sockets with strain relief:
1 retainer clip, height 13.5 mm, 3M (3505-8110)
For sockets without strain relief:
1 retainer clip, height 7.9 mm, 3M (3505-8010)
Latch