PLATFORM WILL NOT CLOSE
1.
Check the hydraulic fluid level in the Reservoir.
GRAVITY DOWN UNITS:
Lower the Platform to the ground. Fill the Reservoir
to about 1” from the top. Do not overfill as this causes spillage.
POWER DOWN UNITS:
Raise the Platform to bed height. Fill the Reservoir to
about the middle. Do not overfill as this causes spillage.
2.
Check the Motor Solenoid (“M”)
for power by placing a 12 Volt Test
Lamp on terminal “A”. If nothing
registers on the Test Lamp, the
Battery or Battery Cables are
faulty. Check the Motor Solenoid
(“M”) itself by placing the 12 Volt
Test Lamp on terminal “B”. If
nothing registers on the Test
Lamp, replace the Motor Solenoid.
If power does register on the Test
Lamp, replace the Motor.
TERMINAL “A”
BATTERY CABLE
TERMINAL
PUMP MOTOR
SOLENOID (“M”)
TERMINAL
“B”
GREEN
WIRE
WHITE
WIRE
Continued Next Page
3.
If the unit has an Emergency Hand Pump attached, be sure the proper
valves are closed. Refer to the Decal on the Pump for proper operation.
4.
Check the Flow Control Valve.
This valve should be open. Adjust
as necessary for speed.
FLOW
CONTROL
VALVE
TERMINAL
“B”
WHITE WIRE