11921
Slauson
A
ve.
Santa
Fe
Springs,
CA.
90670
(800)
227-41
16
FA
X
(888)
771-7713
PAGE 33
PLATFORM RAISES HALFWAY & STOPS
1.
Check the hydraulic fluid level in the Reservoir.
GRAVITY DOWN UNITS:
Lower the Platform to the ground. Fill the Reservoir
to about 1” from the top. Do not overfill as this causes spillage.
POWER DOWN UNITS:
Raise the Platform to bed height. Fill the Reservoir to
about the middle. Do not overfill as this causes spillage.
2.
Check the Battery Cables for damage, and the Battery for a charge.
Replace or recharge as needed. The use of a Voltage Load Tester is
recommended. Check the Circuit Breaker. Reset or replace as needed.
3.
Check for structural damage to the liftgate. Visually inspect for improper
bending of structures that could prevent normal operation. Be sure the unit
has been properly lubricated to prevent binding. Lubricate or replace worn
parts.
4.
A worn Pump or clogged Pump Filter
can cause the unit to lift slowly. Check
the Pump Filter located in the
Reservoir. A worn pump will be
extremly noisy. Replace as necessary.
5.
Check the Pressure Compensation
Valves located at the top of each
Column. They may be partially
plugged.
PUMP FILTER
PRESSURE
COMPENSATION
VALVE
Summary of Contents for BMR-35
Page 48: ......