Setup
Connections
EPOS4 Disk 60/8 Hardware Reference
3-36
CCMC | 2021-10 | rel10276
3.3.9
CAN IN (X14) & CAN OUT (X15)
The Disk CAN is specially designed being commanded and controlled via a Controller Area Network (CAN).
It is preferably used as a slave node in the CANopen network.
Figure 3-27
CAN 1 connector X14 / CAN 2 connector X15
Table 3-42
CAN 1 connector X14 / CAN 2 connector X15 – Pin assignment
Table 3-43
CAN 1 connector X14 / CAN 2 connector X15 – Specifications
Continued on next page.
X14
X15
Pin
Signal
Description
1
CAN high
CAN high bus line
2
CAN low
CAN low bus line
3
—
not connected
4
—
not connected
5
—
not connected
6
CAN V+
CAN external supply (device-internally not in use)
7
GND
Ground
8
—
not connected
9
—
not connected
10
—
not connected
—
Shield
Cable shield
Connector X14; X15
Suitable cables
Suitable plugs
maxon (751388) (
Table 3-10) or
HARTING (09 45 181 9002 XL) or Hirose (IX30G-B-10S-CV(7.0))
X14
X15