© Copyright 2019. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: [email protected]
Page: 3
REV: 12/19/19
Mount Accessories
Pendant:
1.
Fix the tank cover on the NPT ¾” threaded pipe
then tighten the M4 fastening screws.
2.
Connect electrical components.
3.
Use the three M5 socket head screws to fix the
luminaire with a torque value of
5 N-m
.
U-Bracket:
1.
Use the four M8 expansion bolts to fix the bracket to the wall.
2.
Connect electrical components.
3.
Use the three M5 socket head screws to fix the luminaire with a
torque value of
5 N-m
; adjust the angle of the lamp and use the
M4 screws to fix the fixture in place.
step1
step2
Set screw
M4
Socket head cap screws
M5
step3
step1
step2
Socket head cap screws
M5
Screws
M4
(Washers induded) M8
Expansion bolts
step3
Operating Instructions
Hazardous Location HLRS Series
MaxLite Hazardous Location HLRS Series
®