MxL7213 13A Dual Phase EVB User Manual
Set-Up Options
10/15/20
000UMR05
7
Set-Up Options
Jumpers are factory installed per Table 2 to configure the EVB for operation. Jumper and testing options are described in
the next sections. Refer to the product datasheet for additional information.
Jumper J44 MODE
Jumpers J30 RUN1 and J29 RUN2
Jumper J26 TRACK1 SEL
Table 5:
J26 Options
Table 2:
Factory Settings
Jumper
Label
Factory Setting
Description
J44
MODE
Jumper 3-4
FCM
J30
RUN1
Jumper 1-2
On
J29
RUN2
Jumper 1-2
On
J26
TRACK1
Jumper 5-6
Soft-Start
J25
TRACK2
Jumper 5-6
Soft-Start
J45
PHASEMD
No Jumper
90°
Table 3:
J44 Options
Jumper Options
Description
Jumper 1-2
PSM - Pulse Skipping Mode.
Jumper 3-4
FCM - Force Continuous Mode.
Pin 6
Apply an external clock to pin 6 to put both channels into continuous mode, synchronized to the applied clock.
Table 4:
J30, J29 Options
Jumper Options
Description
Jumper 1-2
On. RUN1/2 connected to VIN.
Jumper 2-3
Off. RUN1/2 connected to GND.
Jumper Options
Description
Jumper 1-2
V
OUT2
master track mode.
Jumper 3-4
External master track mode.
Jumper 5-6
Soft start. Track1 connected to cap to GND.