MaxLab 500134 Installation Manual Download Page 1

Passive CCTV Hub Plus (500134)

Installation Guide

P/N: 94-000690-A, SE-000690-A

Summary of Contents for 500134

Page 1: ...Passive CCTV Hub Plus 500134 Installation Guide P N 94 000690 A SE 000690 A...

Page 2: ...ts reserved Printed in Canada No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or othe...

Page 3: ...1 1 Description 4 1 2 Features 4 2 Technical Specifications 5 3 Installation Procedure 6 3 1 Parts List 6 3 2 Product Overview 6 3 3 Pre Installation Checklist 7 3 4 Physical Installation 8 3 5 Insta...

Page 4: ...nected to a 16 channel CCTV power supply for greater ease of installation In order to connect remote power to the hub the 16 channel power cable assembly included with the hub must be used The Passive...

Page 5: ...ss Thru Mode 500022 Wiring Remote 2 wire PTZ control supported via one 1 twisted pair Maximum Distance Up to 4 000 ft 1 2 km depending on the PTZ camera vendor Please consult your CCTV equipment vendo...

Page 6: ...that all pieces are present before proceeding Base Unit Factory configuration Power Thru Mode 500022 16 channel power cable assembly Installation Guide 3 2 Product Overview The external connections of...

Page 7: ...ween a 16 channel CCTV power supply and the hub 2 The hub features a switch at each port to select between Pass Thru Mode 500022 compatible or Power Thru Mode 500024 500029 compatible depending on the...

Page 8: ...tion The Passive CCTV Hub Plus is a 1U 19 rackmount unit The factory default switch settings of each port is Pass Thru Mode 500022 1 Select the final destination for the product in the relay rack and...

Page 9: ...tance between the rack and cameras are within MuxLab specifications 2 Connect a MuxLab passive CCTV Balun MuxLab p n 500000 500009 500022 500023 500024 or 500029 to each CCTV camera video output Pleas...

Page 10: ...twisted pairs and control on one 1 twisted pair set the port switch to Pass Thru Mode 500022 using a small flathead screwdriver as shown in fig 6 Ensure that there is a CCTV Pass Thru Balun 500022 at...

Page 11: ...34 includes a 16 channel 18AWG 2 wire power cable assembly to facilitate connection between the hub and a 16 channel CCTV power supply 9 The lengths of wire leads are different for each port in order...

Page 12: ...is set to Power Thru Mode 500024 500029 three 3 twisted pairs are used for remote power thus supporting greater distance Connect the 16 channel 18 2 power cable assembly to the hub by plugging each te...

Page 13: ...s set to Pass Thru Mode 500022 When the port switch is set to Pass Thru Mode 500022 one 1 twisted pair is used for PTZ control For optimum results it is recommended to use control protocols such as RS...

Page 14: ...rrect not split Picture loses color faded or weak Exceeded distance specifications Lower grade UTP cable is introducing high losses Check DC loop resistance and verify if distance spec is exceeded Red...

Page 15: ...e 500024 500029 Pass Thru Mode 500022 Two 2 Twisted Pairs Voltage Pcam W Vcam1 min V Dist Spec2 max Feet Dist Spec2 max m 12 VDC AC 5 10 80 86 28 12VDC AC camera 10 10 80 43 14 20 10 80 22 7 30 10 80...

Page 16: ...C camera 10 21 60 259 85 20 21 60 130 43 30 21 60 86 28 40 21 60 65 21 50 21 60 52 17 28 VAC 5 21 60 1382 454 24VAC camera 10 21 60 691 227 20 21 60 346 113 30 21 60 230 76 40 21 60 173 57 50 21 60 13...

Page 17: ...RISING OUT OF THE USE OF OR INABILITY TO USE THIS PRODUCT EVEN IF MUXLAB OR AN AUTHORISED MuxLab DEALER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES NOR WILL MUXLAB BE LIABLE FOR ANY CLAIM BY A...

Page 18: ...MuxLab Inc Passive CCTV Hub Plus Installation Guide Page 18...

Page 19: ...MuxLab Inc Passive CCTV Hub Plus Installation Guide Page 19...

Page 20: ...TV Hub Plus Installation Guide Page 20 MuxLab Inc 8495 Dalton Road Mount Royal Quebec Canada H4T 1V5 Tel 1 514 905 0588 Fax 1 514 905 0589 Toll Free North America 877 689 5228 URL www muxlab com E mai...

Reviews: