MAXIMUM Security CURTAIN-Mini Operating & Installation Manual Download Page 1

 

Operating & Installation Guide 

 

CURTAIN-Mini 

 

Remote Controlled

  

Outdoor/Indoor intrusion detector with 

curtain field-of-view 

 
 
 

MAXIMUM

 

Security (1984) Ltd.

 

www.maximum.co.il 

Summary of Contents for CURTAIN-Mini

Page 1: ...Operating Installation Guide CURTAIN Mini Remote Controlled Outdoor Indoor intrusion detector with curtain field of view MAXIMUM Security 1984 Ltd v www maximum co il...

Page 2: ...lso be controlled by Remote Control option 90 0 mounting bracket provided Extremely reliable highly immune to false alarms Selectable PIR detection sensitivity Selectable Microwave sensitivity Auto te...

Page 3: ...on and maximum use of all its benefits please read all parts of this installation and operating manual and follow the step by step instructions INTRODUCTION CURTAIN Mini creates a super narrow protect...

Page 4: ...tect almost any type of material that blocks masks its near field of view It will also detect transparent objects such as clear glass and plastic bags It will activate an alert even if its lens was sp...

Page 5: ...and defeated 3 This product as any other may malfunction or become damaged during regular use or a result of vandalism 4 A comprehensive inspection of the product in terms of proper activity and perfo...

Page 6: ...6 12 APPLICATION 3 10 m 10 m...

Page 7: ...F VIEW DIAGRAMS 2m 10m 15m Microwave 800 0 Side view PIR AND Microwave PIR PIR PIR P I R P I R P I R P I R 10m 15m Microwave 0 Top view PIR AND Microwave 63 cm 30 Detection range of up to 12 meter is...

Page 8: ...8 12 DETECTION SENSITIVITY ADJUSTMENT and WIRING...

Page 9: ...d be performed by the installer ensuring proper operation of the Anti masking channel Study procedure to be performed in two cases 1 Upon connecting the power supply to the detector after about 1 minu...

Page 10: ...n during the study procedure The Red Green LED indicators blink rapidly for about 60 seconds A break of about 20 seconds Green LED indicator are activated The Red Green LED indicators blink rapidly fo...

Page 11: ...ndicators will blink simultaneously during those 2 seconds Test procedure for masking detection Anti masking o At a distance of about 10 cm from the front of the detector place a white piece of paper...

Page 12: ...rance 15V DC 20 mA TAMPER Switch endurance 24V DC 0 1A Warm up time 1 Minute Alarm period 2 Seconds Anti masking relay response time 90 Seconds Max Anti masking relay activation period All time of mas...

Reviews: