DS3171/DS3172/DS3173/DS3174
206
Register Name:
E3G832.RFECR
Register Description:
E3 G.832 Receive Framing Error Count Register
Register Address:
(1,3,5,7)34h
Bit
# 15 14 13 12 11 10 9 8
Name FE15 FE14 FE13 FE12 FE11 FE10 FE9 FE8
Default
0 0 0 0 0 0 0 0
Bit
# 7 6 5 4 3 2 1 0
Name FE7 FE6 FE5 FE4 FE3 FE2 FE1 FE0
Default
0 0 0 0 0 0 0 0
Bits 15 to 0: Framing Error Count (FE[15:0])
– These sixteen bits indicate the number of framing error events on
the incoming E3 data stream. This register is updated via the PMU signal (see Section
Register Name:
E3G832.RPECR
Register Description:
E3 G.832 Receive Parity Error Count Register
Register Address:
(1,3,5,7)36h
Bit
# 15 14 13 12 11 10 9 8
Name PE15 PE14 PE13 PE12 PE11 PE10 PE9 PE8
Default
0 0 0 0 0 0 0 0
Bit
# 7 6 5 4 3 2 1 0
Name PE7 PE6 PE5 PE4 PE3 PE2 PE1 PE0
Default
0 0 0 0 0 0 0 0
Bits 15 to 0: Parity Error Count (PE[15:0])
– These sixteen bits indicate the number of parity (BIP-8) errors
detected on the incoming E3 data stream. This register is updated via the PMU signal (see Section
Register Name:
E3G832.RFBER
Register Description:
E3 G.832 Receive Remote Error Indication Count Register
Register Address:
(1,3,5,7)38h
Bit
# 15 14 13 12 11 10 9 8
Name FBE15 FBE14 FBE13 FBE12 FBE11 FBE10 FBE9 FBE8
Default
0 0 0 0 0 0 0 0
Bit
# 7 6 5 4 3 2 1 0
Name FBE7 FBE6 FBE5 FBE4 FBE3 FBE2 FBE1 FBE0
Default
0 0 0 0 0 0 0 0
Bits 15 to 0: Remote Error Indication Count (FBE[15:0])
– These sixteen bits indicate the number of remote
error indications detected on the incoming E3 data stream. This register is updated via the PMU signal (see
Section