Procedure

1) Go  to 

www.maximintegrated.com/evkitsoft-

ware

 to download the most recent version of the 

Munich board software, 

MUNICH GUI

. Save the 

software to a temporary folder and decompress the  

Munich_GUISetupV2.03.zip file.

2) Connect the USB cable between the Munich board 

and the PC; the USB driver is installed automatically.

3) Ensure that the companion SPI interface device’s 

jumper settings are correct. Refer to your companion 

device’s documentation.

4) Connect the Munich board’s 2x6-pin right-angle con-

nector to the companion device’s 2x6-pin right-angle 

header.

Detailed Description of Software

Graphical User Interface (GUI)

1)  Once the Munich board is connected with the compan-

ion device, open the 

MUNICH GUI.exe

 (double-click) 

software.

2) Start the Munich board software and select the tab 

sheet that corresponds to the companion device as 

shown in 

Figure 5

, the Munich GUI.

3) Press the 

Scan Devices

 pushbutton to scan the 

available Munich boards connected to the computer. 

This allows the user to test multiple companion driver 

boards at the same time. Each Munich board has a 

unique ID that the software determines.

Figure 5. Munich GUI

Figure 5

Summary of Contents for Munich USB2PMB1

Page 1: ...r 1 2A PWM step down DC DC converter MAX1556 a dual high speed USB to multipurpose UART FIFO IC FT2232HL and a 4K MICROWIRE compatible serial EEPROM This Munich adapter board is used to enable USB to...

Page 2: ...esigned to supply power to exter nal boards Santa Fe Campbell Fresno and Corona through the connector X2 It is intended to provide power supply to the interface circuitry present in the connected driv...

Page 3: ...on device s documentation 4 Connect the Munich board s 2x6 pin right angle con nector to the companion device s 2x6 pin right angle header Detailed Description of Software Graphical User Interface GUI...

Page 4: ...rd is connected See Figure 6 Connecting Multiple Boards When connecting multiple boards such as Campbell and Cupertino at the same time to two separate Munich boards perform Steps 1 to 3 for each devi...

Page 5: ...changes its text to Stop Sampling and the user would not be able to discon nect the board from the software until the user clicks the Stop Sampling button 3 Sample Rate This drop down box option allow...

Page 6: ...s the temperature mea sured from IFM TA3231 Temp Sensor This sensor sinks sources current proportional to the temperature measured The shunt current and the temperature measured would be indi cated th...

Page 7: ...Maxim Integrated 7 www maximintegrated com USB2PMB1 Adapter Board Evaluates Munich USB2PMB1 Figure 9a Plot Configuration Options Figure 10 Histogram Display on Munich Campbell GUI Figure 9a Figure 10...

Page 8: ...ale the current measured ii Offset The offset calibration is done by forcing a 0V input voltage or 0mA current to obtain the plot counts This plot counts value if other than 0 should be fed in the off...

Page 9: ...el input has seven differ ent input range options for selection See Figure 12 2 Sampling a Sample Once This pushbutton tab allows dis crete sampling b Sample Continuously This feature allows continuou...

Page 10: ...down box menu to choose to aver age of the discrete values sampled For instance if 16 is selected it takes the first 16 samples of the sample shot the user takes then averages them and shows the numbe...

Page 11: ...Maxim Integrated 11 www maximintegrated com USB2PMB1 Adapter Board Evaluates Munich USB2PMB1 Figure 13 Calibration Display on Munich Cupertino GUI...

Page 12: ...c Sample Rate This drop down box option allows the user to choose the sample rate or the number of samples per second d Sample Count This drop down box option allows the user to choose the number of...

Page 13: ...he user wishes to calibrate this option enables a real time calibration i Offset The offset calibration is done by forcing a 0V input voltage to obtain the plot counts This plot counts value if other...

Page 14: ...luates Munich USB2PMB1 Figure 15 Munich Corona GUI Denotes RoHS compliant For further details refer to the MAX11300PMB1 Peripheral Module and Munich USB2PMB1 Adapter Board Quick Start Guide at www max...

Page 15: ...axim Integrated logo are trademarks of Maxim Integrated Products Inc 2015 Maxim Integrated Products Inc 15 USB2PMB1 Adapter Board Evaluates Munich USB2PMB1 REVISION NUMBER REVISION DATE DESCRIPTION PA...

Reviews: