MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.4 Timers/Counters
10.4.4.1.9
TMRn_INTFL
TMRn_INTFL.timer0
Field
Bits
Default
Access
Description
timer0
0
0
W1C
Interrupt Flag for 32-bit Timer / 16-bit Timer 0
Hardware sets this flag to 1 when the timer reaches the terminal count or a capture value is obtained or when the input pad is deasserted in Gated mode.
Write 1 to clear this flag to 0.
TMRn_INTFL.timer1
Field
Bits
Default
Access
Description
timer1
1
0
W1C
Interrupt Flag for 16-bit Timer 1
Hardware sets this flag to 1 when the timer reaches the terminal count or a capture value is obtained or when the input pad is deasserted in Gated mode.
Write 1 to clear this flag to 0.
10.4.4.1.10
TMRn_INTEN
TMRn_INTEN.timer0
Field
Bits
Default
Access
Description
timer0
0
0
R/W
Interrupt Enable for 32-bit Timer / 16-bit Timer 0
Enable/disable setting to allow a timer interrupt to be triggered when the corresponding interrupt flag is set.
0: Interrupt disabled (no interrupt will be triggered) 1: Interrupt enabled (interrupt may trigger normally)
TMRn_INTEN.timer1
Rev.1.3 April 2015
Maxim Integrated
Page 606