MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.3 Real Time Clock (RTC)
RTCTMR_INTEN.trim
Field
Bits
Default
Access
Description
trim
4
0
R/W
RTC Trim Adjust Event Interrupt Enable
• 0: Disabled.
• 1: The RTC Trim Adjust Event Interrupt is enabled.
10.3.5.1.8
RTCTMR_PRESCALE
RTCTMR_PRESCALE.width_selection
Field
Bits
Default
Access
Description
width_selection
3:0
0000b (RTC POR only)
R/W
RTC Timer Prescale Setting
This field selects the initial value that is reloaded into the RTC timer prescale counter each time the prescale counter reaches 0 (or when the RTC timer is first
initialized). The larger the initial prescale value, the slower the overall RTC timer will run.
• 0000b: 000h (RTC timer runs at 4kHz)
• 0001b: 001h (2kHz)
• 0010b: 003h (1kHz)
• 0011b: 007h (512Hz)
• 0100b: 00Fh (256Hz)
• 0101b: 01Fh (128Hz)
• 0110b: 03Fh (64Hz)
• 0111b: 07Fh (32Hz)
• 1000b: 0FFh (16Hz)
• 1001b: 1FFh (8Hz)
Rev.1.3 April 2015
Maxim Integrated
Page 579